Al/Cu-Leiter XLPE-Isoliertes, dünnes/Dickes Stahlarmoriertes PE-/PVC-Ummanteltes Netzkabel für werkseitigen Preis

China 
                                 Al/Cu-Leiter XLPE-Isoliertes, dünnes/Dickes Stahlarmoriertes PE-/PVC-Ummanteltes Netzkabel für werkseitigen Preis                              Herstellung und Lieferant

Al/Cu-Leiter XLPE-Isoliertes, dünnes/Dickes Stahlarmoriertes PE-/PVC-Ummanteltes Netzkabel für werkseitigen Preis image

Get Latest Price Request a quote

Basis Info

Modell Nr..
power cable

Art
Isolierte

Leitertyp
Stranded

Anwendung
U-Bahn

Leitermaterial
Kupfer

Mantelmaterial
PVC

Isoliermaterial
XLPE

Material Form
Runddraht

Anwendungsbereiche
Flammschutzmittel

Bescheinigung
ISO9001 ,
CE ,
CCC ,
RoHS

Zusätzliche Informationen.

Warenzeichen
Huatong

Verpackung
All Wooden, Coils or as Per Your Request Package

Herkunft
China

HS-Code
8544492100

Produktionskapazität
5000tons /Month

Produktbeschreibung

Al/Cu Conductor XLPE Insulated Thin/Thick steel armored PE /pvc Sheathed Power Cable for factory price
26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.GB/T12706-2002 standard(The same as IEC60502).

Executive Standard: 
It is manufacture under GB/T12706-2002 standard(The same as IEC60502). 
Application: 
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. 
It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry 
and communication in complete replace of oil immersed paper insulated power cable and in partial replace
 of PVC insulated power cable. 
Using features: 
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV. 
2. No. of core: Single-core, Three-core. 
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250. 
4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997. 
5. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated. 
6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter. 
7. Working Frequency Voltage Test:. 
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture. 
For cable with Uo of 3.6kv~18kV: 3.5Uo/5min without puncture. 
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture. 
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
 
Installation 
This cable can be installed in duct, tray or direct burial. It is recommended that the installation instructions indicated
 by the Local Electric Code, or any equivalent, be followed,so that the safeguarding of persons and the integrity
 of the product will not be affected by eciencies in the installation. 
 
This series includes:
 
Copper (aluminum) core, XLPE insulated and sheathed power cables. 
Copper (aluminum) core, XLPE insulated, PE sheathed power cables. 
Copper (aluminum) core, XLPE insulated, steel tape armoring PVC sheathed power cables. 
Copper (aluminum) core, XLPE insulated, steel tape armoring, PE sheathed power cables. 
Copper (aluminum) core, XLPE insulated, steel wire armoring, PVC sheathed power Cables. 
Copper (aluminum) core, XLPE insulated, steel wire armoring, PE sheathed power cables 
Rated voltage: 0.6/1kV, 3.6/6kV. 
Number of cores: 1 to 6. 
Relative manufacturing standards: IEC60505, BS, DIN.
 
Packing: Wooden drum, steel wooden drum.
 
Power Cable 
-Conductor: 
Solid or stranded copper 
-Insulation: 
Cross-linked polyethylene( XLPE or PVC) 
-Circuit Identication: 
The insulation shall be red, black 
-Filler: 
Polypropylene lament with lapped binding tape 
-Inner Sheath: 
Polyvinyl chloride (Black) 
-Armor: 
Galvanized steel wire 
-Core-covering: 
Binding tape 
-Outer Sheath: 
Polyvinyl chloride (Black) 
-Application: 
For use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time. 
-Standards / Testing Specications: 
IEC 60502-1. 
 

Type Description Application n
Cu Al
YJV YJLV XLPE insulation PVC sheath power cable To be laid indoors, in tunnel or pipe, the cable couldn't bear mechanical force outside 
YJY YJLY XLPE insulation PE sheath power cable
YJV22 YJLV22  XLPE insulation, steel tape armor,  PVC sheath power cable  
To be laid underground, the cable could bear certain mechanical force, but it couldn't bear great pulling force.
YJV23 YJLV23 XLPE insulation, steel tape armor,  PE sheath power cable
YJV62 YJLV62 XLPE insulation, have no the magnetism steel tape armor,  PE sheath power cable
YJV32 YJLV32 XLPE insulation, thin steel-wire  armor,  PVC sheath power cable Be applicable to the  water inside well and fall in the bad soil, the cable cans bear the equal dint outside the machine with pull the dint
 
.
YJV72 YJLV72 XLPE insulation, have no the magnetism thick steel-wire  armor,  PVC sheath power cable
YJV42 YJLV42 XLPE insulation, thick steel-wire  armor,  PVC sheath power cable Be applicable to the underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint.
Special
Note
The single-core magnetism material packs the cable is not suitable for to use for the AC power supply back track, the necessity hour eligibility uses the single-core 62 or 72 type pack the cable.
Disallow the cent to cross the magnetism piping mutually when single-core cable establish, the in order to prevent results in the descent that cable transport electric current ability.

       

Related Product:

     Packing:
1.We guarantee to ship goods out 5-10 working days after payment confirmation. 
 2.If you didn't receive the item after 30 days,please feel free to contact us.We will make all our to resolve the problem.
Warranty:
  1.For wrong shipped items, Please contact us, We will arrange to deliver the correct items.
 2.For defective or faulty products,please contact us first,We will resolved your issues,thanks !
     FAQ
Q:How to order 
1. Please tell us what kind of model you need.
2. We make Proforma Invoice to you.
3. Please check and confirm the Proforma Invoice.
4.Once we confirmed the order,please pay it soon.
5. After payment , all goods will be sent  within 10 working days as usual.
 Q. The MOQ
I am glad to accept a small order to test the market,While kindly remind, the more the quantity, the better the price.
 Q:What is the quality of the goods
Please trust us without any doubt ,all products we produce with CE,PCCC,SABS,certified .
 Q. If rigid conductor cable was not I want, what should I do?
If you find this rigid conductor cable is not exactly meet what you need. Please send us emails about your inquiry details. We will give you solution within 2 hours!  

Advantage:
       We have a very strict quality controling system which promise that cable we produce are always of best quality!Of course , if you have some good ideas that you want us to develop or reproduced, please feel free to send us your product image or design artwork, we are also pleased to become your Original Equipment Manufacture.We not only promise the good quality but also stable quality . Customer no need usually change suppliers again!We are sincerely looking for your cooperation!

 

 

Wer wir sind China Al/Cu-Leiter XLPE-Isoliertes, dünnes/Dickes Stahlarmoriertes PE-/PVC-Ummanteltes Netzkabel für werkseitigen Preis Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.

Get Latest Price Request a quote

Popular Al/Cu-Leiter XLPE-Isoliertes Produkte

Al/Cu-Leiter XLPE-Isoliertes, dünnes/Dickes PE-Ummanteltes Netzkabel aus Stahl

Popular dünnes/Dickes Stahlarmoriertes PE-/PVC-Ummanteltes Netzkabel für werkseitigen Preis Produkte

  • No related articles
  • Popular huatongcable Produkte

    Gesichtsmaske-Wegwerfschablone

    ACSR Blanker Oberleiter ASTM Osprey Ibis Linnet

    AAAC Alton (Alle Leiter Aus Aluminiumlegierung 48,69 MCM)

    Alle Aaaac AAAC ASTM BS IEC DIN CSA 155,4 Kcmil Anaheim

    Alle Aaaac AAAC ASTM BS IEC DIN CSA 6AWG

    AAC-Leiter, Blank, Leiter BS215, Wesp, Schmetterling, Ant Mosquito

    Popular leistung-kabel Produkte

    0.6/1kv~26/35kv XLPE Insulated Power Cable

    HauptUd Cable, 35 KV, Cu/Tr-XLPE/Neutral/PVC (AEIC CS 8/ICEA S-94-649)

    0.6/1kv N2xry Na2xry XLPE Insulated und Sheated SWA Power Cable

    U-1000 Arvfv, Leistung-Kabel, 0.6/1 KV, Al/XLPE/PVC/Sta/PVC (N-Düngung C 32-322)

    Na2xsey, 3.6/6 KV Power Cable, 3/C, Al/XLPE/Cts/PVC (HD 620/DIN Vde 0276-620)

    Aluminiumleiter XLPE Netzkabel 0,6/1 kv Niederspannung

    Tags: , , , ,

    SCHNELLER UND ZUVERLÄSSIGER SERVICE FÜR IHR PROJEKT

    Wenden Sie sich noch heute an unsere geschulten Experten, um Ihre perfekte Stromversorgungslösung zu finden.

    STELLE EINE FRAGE