Hochwertiges Kabel für das ABC-Antennenbündel mit 33 kv Mittelspannung
Hochwertiges Kabel für das ABC-Antennenbündel mit 33 kv Mittelspannung image
Get Latest Price Request a quote
Basis Info
Oben ,
Industriell ,
Kraftwerk
CCC ,
CE ,
UL
Zusätzliche Informationen.
Produktbeschreibung
Aluminium Secondary UD Cable
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR.One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1.B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2.B-231 Aluminum conductors, Concentric-Lay-Stranded.
3.B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4.B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5.B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6.Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1.Rated Voltage:0.6/1kV
2.Cable installation temperature not less than -20°C
3.Max. temperature of cable at short circuit(The max. duration does not exceed 5 minutes)
For XLPE insulation is 250°C.
For HDPE insulation is 150 °C.
4.The Max. bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1.Duplex Service Drop:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
2.Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
3.Quadruplex Service Drop: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
ASTM B-230, B-231 and ICEA S-66-524
UL Standard 854 for type USE
Federal Specification JC-30B NEC
Code Name | Phase Conductor | Neutral | Single Phase Conductor(in) | Outside diameter(in) | Weight Per 1000ft (lbls) | Ampacity | |||||
Size AWG | Strand | Insulation Thickness (mls) | Size AWG | Strand | Insulation Thickness (mls) | Direct Burial | In Duct | ||||
Tulsa | 4 | 7/w | 60 | 4 | 7/w | 60 | .345 | .833 | 258 | 119 | 85 |
Dyke | 2 | 7/w | 60 | 4 | 7/w | 60 | .403 | .938 | 346 | 153 | 115 |
Wittenberg | 2 | 7/w | 60 | 2 | 7/w | 60 | .403 | .973 | 375 | 153 | 115 |
Notre Dame | 1/0 | 19/w | 80 | 2 | 7/w | 60 | .522 | 1.188 | 541 | 198 | 150 |
Purdue | 1/0 | 19/w | 80 | 1/0 | 19/w | 80 | .522 | 1.260 | 596 | 198 | 150 |
Syracuse | 2/0 | 19/w | 80 | 1/0 | 19/w | 80 | .566 | 1.316 | 664 | 225 | 170 |
Lafayette | 2/0 | 19/w | 80 | 2/0 | 19/w | 80 | .566 | 1.367 | 720 | 225 | 170 |
Swarthmore | 3/0 | 19/w | 80 | 1/0 | 19/w | 80 | .616 | 1.430 | 805 | 250 | 195 |
Davidson | 3/0 | 19/w | 80 | 3/0 | 19/w | 80 | .616 | 1.487 | 874 | 250 | 195 |
Wake Forest | 4/0 | 19/w | 80 | 2/0 | 19/w | 80 | .672 | 1.560 | 979 | 290 | 225 |
Earlham | 4/0 | 19/w | 80 | 4/0 | 19/w | 80 | .672 | 1.623 | 1066 | 290 | 225 |
Slippery Rock | 350 | 37/w | 95 | 4/0 | 19/w | 80 | .851 | 1.945 | 1544 | 385 | 305 |
Wofford | 500 | 37/w | 95 | 350 | 37/w | 95 | .851 | 2.348 | 2174 | 467 | 420 |
Windham | 750 | 61/w | 110 | 500 | 37/w | 95 | .979 | 2.850 | 2542 | 615 | 492 |
Wer wir sind China Hochwertiges Kabel für das ABC-Antennenbündel mit 33 kv Mittelspannung Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.
Get Latest Price Request a quote
Popular 33kv Service Drop Produkte
Popular ABC Produkte
Hochwertiges ABC-Kabel aus Aluminium, 1/0AWG 2/0AWG 4/0AWG
Kabel-Distanzstück ABC-Kabel, im Lieferumfang der Overhead-Elektroübertragungsantenne Enthalten
ABC-Kabel Oberleitungspaket Kabel Aluminiumantenne Kabel
XLPE-Isolierte Antennenkabel, Im Lieferumfang Enthaltene Leiter ABC-Kabel
Luftbündel-Kabel ABC zu ohne 1418 Größe 3X70+54.6
Kabel-Abc-Kabel für das Kabel für das elektrische Getriebe über Kopf
Popular Hochwertiges Kabel für das ABC-Antennenbündel mit 33 kv Mittelspannung Produkte
Popular huatongcable Produkte
Rabus/Sorbus/Redwood/Fir AAAC-Leiter mit Hochwertigem, Niedrigem Preis
Leiter aus Aluminiumlegierung BS 3242 für Oak Für Das Kraftübertragung Über Kopf
AAAAC 500 mm2 Überleitungs-Alu-Leiter
AAAC-Leiter ASTM B399 Aluminiumlegierung 6201-T81 50 mm2
Huatong Brand Feuerverzinkter Stahldraht, 7 Litzen, Swg-Stabdraht für Stahlpol
Overhead Triplex Service Drop Artemia Luftbündelkabel für Übertragungsleitung
Tags: 33kv Service Drop, ABC, Hochwertiges Kabel für das ABC-Antennenbündel mit 33 kv Mittelspannung, huatongcable