Low Tension Copper Conductor XLPE Power Cable
Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Prpperty:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Specification:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.
1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm2 | mm | mm | mm | mm | mm | mm | mm | kg/m | kg/m |
3 X 25 | 6.0 | 2.5 | 0.1 | 1.2 | 0.2 | 1.9 | 37.9 | 1.87 | 2.32 |
3 X 35 | 6.9 | 2.5 | 0.1 | 1.3 | 0.5 | 2.0 | 41.5 | 2.10 | 2.73 |
3 X50 | 8.2 | 2.5 | 0.1 | 1.3 | 0.5 | 2.0 | 44.3 | 2.37 | 3.22 |
3 X 70 | 9.7 | 2.5 | 0.1 | 1.4 | 0.5 | 2.1 | 47.9 | 2.77 | 4.00 |
3 X 95 | 11.3 | 2.5 | 0.1 | 1.4 | 0.5 | 2.2 | 51.6 | 3.21 | 4.91 |
3 X 120 | 12.8 | 2.5 | 0.1 | 1.5 | 0.5 | 2.4 | 55.4 | 3.69 | 5.84 |
3 X 150 | 14.2 | 2.5 | 0.1 | 1.5 | 0.5 | 2.5 | 58.6 | 4.15 | 6.85 |
3 X 185 | 15.9 | 2.5 | 0.1 | 1.5 | 0.5 | 2.6 | 62.5 | 4.73 | 8.11 |
3 X 240 | 18.3 | 2.6 | 0.1 | 1.6 | 0.5 | 2.7 | 68.5 | 5.62 | 10.05 |
3 X 300 | 20.4 | 2.8 | 0.1 | 1.7 | 0.5 | 2.9 | 74.5 | 6.55 | 12.11 |
3 X 400 | 23.2 | 3.0 | 0.1 | 1.9 | 0.8 | 3.2 | 83.6 | 8.78 | 15.86 |
3 X 500 | 26.4 | 3.2 | 0.1 | 2.1 | 0.8 | 3.4 | 93.0 | 10.52 | 18.85 |
2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm2 | mm | mm | mm | mm | mm | mm | mm | kg/m | kg/m |
3 X 25 | 6.0 | 3.4 | 0.1 | 1.3 | 0.5 | 2.0 | 43.4 | 2.16 | 2.61 |
3 X 35 | 6.9 | 3.4 | 0.1 | 1.3 | 0.5 | 2.0 | 45.4 | 2.36 | 2.99 |
3 X50 | 8.2 | 3.4 | 0.1 | 1.4 | 0.5 | 2.2 | 48.8 | 2.69 | 3.54 |
3 X 70 | 9.7 | 3.4 | 0.1 | 1.5 | 0.5 | 2.3 | 52.4 | 3.10 | 4.33 |
3 X 95 | 11.3 | 3.4 | 0.1 | 1.5 | 0.5 | 2.4 | 56.1 | 3.56 | 5.26 |
3 X 120 | 12.8 | 3.4 | 0.1 | 1.5 | 0.5 | 2.5 | 59.5 | 4.04 | 6.19 |
3 X 150 | 14.2 | 3.4 | 0.1 | 1.5 | 0.5 | 2.6 | 62.7 | 4.49 | 7.19 |
3 X 185 | 15.9 | 3.4 | 0.1 | 1.6 | 0.5 | 2.6 | 66.6 | 5.12 | 8.49 |
3 X 240 | 18.3 | 3.4 | 0.1 | 1.7 | 0.5 | 2.8 | 72.4 | 5.99 | 10.42 |
3 X 300 | 20.4 | 3.4 | 0.1 | 1.8 | 0.5 | 3.0 | 77.5 | 6.86 | 12.42 |
3 X 400 | 23.2 | 3.4 | 0.1 | 1.9 | 0.8 | 3.2 | 85.4 | 8.97 | 16.05 |
3 X 500 | 26.4 | 3.4 | 0.1 | 2.0 | 0.8 | 3.4 | 93.7 | 10.65 | 19.50 |
3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm2 | mm | mm | mm | mm | mm | mm | mm | kg/m | kg/m |
3 X 25 | 6.0 | 4.5 | 0.1 | 1.4 | 0.5 | 2.1 | 48.6 | 2.53 | 2.98 |
3 X 35 | 6.9 | 4.5 | 0.1 | 1.4 | 0.5 | 2.2 | 50.7 | 2.76 | 3.39 |
3 X50 | 8.2 | 4.5 | 0.1 | 1.5 | 0.5 | 2.3 | 53.9 | 3.10 | 3.95 |
3 X 70 | 9.7 | 4.5 | 0.1 | 1.5 | 0.5 | 2.4 | 57.4 | 3.51 | 4.74 |
3 X 95 | 11.3 | 4.5 | 0.1 | 1.5 | 0.5 | 2.6 | 61.2 | 4.05 | 5.75 |
3 X 120 | 12.8 | 4.5 | 0.1 | 1.6 | 0.5 | 2.6 | 64.7 | 4.56 | 6.72 |
3 X 150 | 14.2 | 4.5 | 0.1 | 1.6 | 0.5 | 2.7 | 67.9 | 5.04 | 7.74 |
3 X 185 | 15.9 | 4.5 | 0.1 | 1.7 | 0.5 | 2.8 | 71.9 | 5.66 | 9.04 |
3 X 240 | 18.3 | 4.5 | 0.1 | 1.8 | 0.5 | 3.0 | 77.7 | 6.56 | 11.00 |
3 X 300 | 20.4 | 4.5 | 0.1 | 1.9 | 0.8 | 3.2 | 84.1 | 8.39 | 13.96 |
3 X 400 | 23.2 | 4.5 | 0.1 | 2.0 | 0.8 | 3.3 | 90.5 | 9.71 | 16.79 |
3 X 500 | 26.4 | 4.5 | 0.1 | 2.1 | 0.8 | 3.5 | 98.8 | 11.45 | 20.57 |
4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm2 | mm | mm | mm | mm | mm | mm | mm | kg/m | kg/m |
3 X 25 | |||||||||
3 X 35 | 6.9 | 5.5 | 0.1 | 1.5 | 0.5 | 2.4 | 55.6 | 3.14 | 3.77 |
3 X50 | 8.2 | 5.5 | 0.1 | 1.5 | 0.5 | 2.5 | 58.6 | 3.49 | 4.34 |
3 X 70 | 9.7 | 5.5 | 0.1 | 1.5 | 0.5 | 2.6 | 62.1 | 3.93 | 5.16 |
3 X 95 | 11.3 | 5.5 | 0.1 | 1.6 | 0.5 | 2.6 | 65.7 | 4.46 | 6.16 |
3 X 120 | 12.8 | 5.5 | 0.1 | 1.7 | 0.5 | 2.7 | 69.4 | 5.00 | 7.15 |
3 X 150 | 14.2 | 5.5 | 0.1 | 1.7 | 0.5 | 2.8 | 72.6 | 5.49 | 8.19 |
3 X 185 | 15.9 | 5.5 | 0.1 | 1.8 | 0.5 | 3.0 | 76.9 | 6.16 | 9.53 |
3 X 240 | 18.3 | 5.5 | 0.1 | 1.9 | 0.8 | 3.2 | 83.9 | 7.87 | 12.31 |
3 X 300 | 20.4 | 5.5 | 0.1 | 2.0 | 0.8 | 3.2 | 88.6 | 8.96 | 14.52 |
3 X 400 | 23.2 | 5.5 | 0.1 | 2.1 | 0.8 | 3.5 | 95.4 | 10.35 | 17.43 |
3 X 500 | 26.4 | 5.5 | 0.1 | 2.2 | 0.8 | 3.7 | 103.7 | 12.45 | 20.23 |
5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm2 | mm | mm | mm | mm | mm | mm | mm | kg/m | kg/m |
3 X 25 | |||||||||
3 X 35 | |||||||||
3 X50 | 8.2 | 8.0 | 0.1 | 1.7 | 0.5 | 2.8 | 70.4 | 4.56 | 5.41 |
3 X 70 | 9.7 | 8.0 | 0.1 | 1.7 | 0.5 | 2.9 | 73.9 | 5.04 | 6.26 |
3 X 95 | 11.3 | 8.0 | 0.1 | 1.8 | 0.5 | 3.0 | 77.7 | 5.62 | 7.32 |
3 X 120 | 12.8 | 8.0 | 0.1 | 1.9 | 0.8 | 3.2 | 82.8 | 6.99 | 9.15 |
3 X 150 | 14.2 | 8.0 | 0.1 | 1.9 | 0.8 | 3.2 | 85.8 | 7.56 | 10.26 |
3 X 185 | 15.9 | 8.0 | 0.1 | 2.0 | 0.8 | 3.3 | 89.9 | 8.30 | 11.67 |
3 X 240 | 18.3 | 8.0 | 0.1 | 2.1 | 0.8 | 3.5 | 95.7 | 9.36 | 13.79 |
3 X 300 | 20.4 | 8.0 | 0.1 | 2.2 | 0.8 | 3.6 | 100.6 | 10.51 | 16.07 |
3 X 400 | 23.2 | 8.0 | 0.1 | 2.3 | 0.8 | 3.8 | 107.2 | 11.99 | 19.07 |
3 X 500 | 26.4 | 8.0 | 0.1 | 2.4 | 0.8 | 4.0 | 120.1 | 14.15 | 23.85 |
Wer wir sind China Leistung-Kabel des Niederspannung-Kupfer-Leiter-XLPE Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.
Get Latest Price Request a quote
Popular Isolierkabel Produkte
Niederspannungs-Leiter-XLPE Isolierzusammengerolltes Luftkabel
Kurbelgehäuse-Belüftung Isolierelektrischer Draht der energien-0.6/1kv/Seilzug
Isolierkabel, Draht, Energien-Kabel
Niederspannungs-Aluminiumenergien-Kabel-geerdetes Kabel
Popular jpcable99 Produkte
Guter Preis 50mm2 120mm2 240mm2 des obenliegenden AAAC Leiter-Kabels
Galvanisierter Stahldraht/Stränge (GSW)
240 mm2 Kupferleiter PVC-isoliertes PVC-ummanteltes Kabel
AAAC Leiter aller Draht des Aluminiumlegierung-Leiter-AAAC
High Quality Service Drop Aerial Bundled Cable
Popular Leistung-Kabel des Niederspannung-Kupfer-Leiter-XLPE Produkte
Popular pvc isolierkabel Produkte
0,6/1 kv Al/XLPE/PVC-Kabel, 4-adrig, 35 mm2
PVC-Isoliertes Kabel BVVB Flachdraht
Kupfernes Leiter-XLPE Isolierkabel vom China-Fachmann-Hersteller
Mehradriges Kabel Vvmv Vvmv-K PVC/PVC/SWA/PVC-Panzerkabel
PVC-Isolierung Aluminium/Kupfer-Stromkabel für den Bau
Netzkabel CU/PVC/Sta/PVC 4 x 50 mm2
Tags: Isolierkabel, jpcable99, Leistung-Kabel des Niederspannung-Kupfer-Leiter-XLPE, pvc isolierkabel