600/1000V, Triplex Aluminium Service Drop Cable, 2/0AWG

China 
                                 600/1000V, Triplex Aluminium Service Drop Cable, 2/0AWG                              Herstellung und Lieferant

600/1000V, Triplex Aluminium Service Drop Cable, 2/0AWG image

Get Latest Price Request a quote

Basis Info

Modell Nr..
Triplex cable 2/0AWG

Zusätzliche Informationen.

Warenzeichen
Yifang Cable

Verpackung
Wooden Drum or Wooden-Steel Drum

Standard
CE SABS RoHS SGS UL CCC

Herkunft
Zhengzhou, China

HS-Code
8544492100

Produktionskapazität
300km/Month

Produktbeschreibung

Triplex Aluminum Service Drop Cable

Code Word Phase conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+
Size (AWG) Stranding Insul. Thick. (mils) Size (AWG) Size (kcmil) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
AAAC 6201 ALLOY FULL NEUTRAL MESSENGER
Minex 6 1 45 6 30.58 7 1110 101 101 85 70
Hippa 6 7 45 6 30.58 7 1110 107 107 85 70
Prawn 4 1 45 4 48.69 7 1760 152 152 115 90
Barnacle 4 7 45 4 48.69 7 1760 160 160 115 90
Shrimp 2 7 45 2 77.47 7 2800 243 243 150 120
Gammarus 1/0 7 60 1/0 123.3 7 4460 390 390 205 160
Leda 1/0 9 60 1/0 123.3 7 4460 384 384 205 160
Dunganese 2/0 7 60 2/0 155.4 7 5390 474 474 235 185
Cyclops 2/0 11 60 2/0 155.4 7 5390 474 474 235 185
Flustra 3/0 17 60 3/0 195.7 7 6790 587 587 275 215
Lepas 4/0 18 60 4/0 246.9 7 8560 728 728 315 245
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

Code Word Phase conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+
Size (AWG) Stranding Insul. Thick. (mils) Size (AWG) Size (kcmil) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
AAAC 6201 ALLOY REDUCED NEUTRAL MESSANGER
Artemia 4 1 45 6 30.58 7 1110 135 135 115 90
Crab 4 7 45 6 30.58 7 1110 143 143 115 90
Solaster 2 7 45 4 48.69 7 1760 216 216 150 120
Sandcrab 1/0 7 60 2 77.47 7 2800 347 347 205 160
Echinus 1/0 9 60 2 77.47 7 2800 341 341 205 160
Crayfish 2/0 7/w 60 mls 2/0 7 2510 485.8 455.3 235 Amps 185 Amps
Sipho 2/0 7/w 60 mls 2/0 7 2510 485.8 455.3 235 Amps 185 Amps
Fulgar 3/0 17 60 1/0 123.3 7 4460 519 519 275 215
Arca 4/0 18 60 2/0 155.4 7 5390 643 643 315 245
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.
Code Word Phase conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+……………
Size (AWG) Stranding Insul. Thick. (mils) Size (AWG) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
AAC NEUTRAL-MESSENGER
Haiotis 6 7/w 45 mls 6 7 563 109.1 101.6 85 Amps 70 Amps
Patella 6 7 45 6 7 563 103 103 85 70
Fusus 4 7/w 45 mls 4 7 881 161.8 151.7 115 Amps 90 Amps
Oyster 4 7 45 4 7 881 154 154 115 90
Clam 2 7 45 2 7 1350 233 233 150 120
Murex 1/0 7 60 1/0 7 1990 374 374 205 160
Purpura 1/0 9 60 1/0 7 1990 368 368 205 160
Nassa 2/0 7 60 2/0 7 2510 462 462 235 185
Melita 3/0 17 60 3/0 19 3310 562 562 275 215
Portunus 4/0 18 60 4/0 19 4020 696 696 315 245
Nannynose 336.4 19 80 336.4 19 6146 1118 1118 420 325
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

Code Word Phase conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+
Size (AWG) Stranding Insul. Thick. (mils) Size (AWG) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
ASCR NEUTRAL-MESSENGER
Paludina 6 1 45 6 6/1 1190 109 109 85 70
Voluta 6 7 45 6 6/1 1190 114 114 86 70
Whelk 4 1 45 4 6/1 1860 164 115 90
Periwinkle 4 7 45 4 6/1 1860 172 172 115 90
Conch 2 7 60 1/0 6/1 4380 420 420 205 160
Neritina 1/0 7 60 1/0 6/1 4380 420 420 205 160
Cenia 1/0 9 60 1/0 6/1 4380 414 414 205 160
Runcina 2/0 7 60 2/0 6/1 5310 520 520 235 185
Triton 2/0 11 60 2/0 6/1 5310 512 512 235 185
Mursia 3/0 17 60 3/0 6/1 6620 635 635 275 215
Zuzara 4/0 18 60 4/0 6/1 8350 789 789 315 245
Limpet 336.4 19 80 336.4 18/1 8680 1167 1167 420 325
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

Code Word Phase conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+
Size (AWG) Stranding Insul. Thick. (mils) Size (AWG) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
ASCR REDUCED NEUTRAL-MESSENGER
Scallop 4 1 45 6 6/1 1190 142 115 90
Strombus 4 7 45 6 6/1 1190 151 151 115 90
Cockle 2 7 45 4 6/1 1190 220 220 150 120
Janthina 1/0 7 60 2 6/1 2853 366 366 205 160
Ranella 1/0 9 60 2 6/1 2853 360 360 205 160
Cavolinia 2/0 7 60 1 6/1 3550 453 453 235 185
Clio 2/0 11 60 1 6/1 3550 444 444 235 185
Sanddollar 3/0 19/w 60 mls 1/0 6/1 4380 565 552 275 Amps 215 Amps
Aega 3/0 17 60 1/0 6/1 4380 549 549 275 215
Cuttlefish 4/0 19/w 60 mls 2/0 6/1 5310 699 684 315 Amps 245 Amps
Cerapus 4/0 18 60 2/0 6/1 5310 681 681 315 245
Cowery 336.4 19 80 mls 336/4 18/1 8680 1209 1167 420 Amps 325 Amps
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

There is a lot of debate still going on as to whether copper is better for electrical purposes or aluminum. If price was not a critical factor, most would suggest going in for silver as it is said to be the best conductor of electricity but has a low strength. However, when it comes to electrical wiring, price is a factor, as is efficiency.
Applications:
To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene Insulation or 90°C maximum for crosslinked insulation.
Construction:
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR or 6201 alloy neutral messenger.
Standards:
B-230 Aluminum Wire 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.
There is a lot of debate still going on as to whether copper is better for electrical purposes or aluminum. If price was not a critical factor, most would suggest going in for silver as it is said to be the best conductor of electricity but has a low strength. However, when it comes to electrical wiring, price is a factor, as is efficiency.

Wer wir sind China 600/1000V, Triplex Aluminium Service Drop Cable, 2/0AWG Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.

Get Latest Price Request a quote

Popular 2/0AWG Produkte

Hochspannungs-Überkopfkabel 15-35kv Baumdraht ACSR 1/0AWG, 2/0AWG, 3/0 AWG, 4/0 AWG, 336,4 MCM

ASTM Standard1/0awg, 2/0AWG, Aluminiumleiter 3/0AWG für Übertragung AAC

Triplex-Servicefall, ABC-Kabel, 2/0AWG, Cyclops LT-Antennenkabel ab 1100V

Triplex-Servicefall, ABC-Kabel, 2/0AWG, Cyclops LT-Antennenkabel ab 1100V

Popular 600/1000v Produkte

Konzentrisches Kabel, Airdac Kabel

Elektrischer Strom-Kabel-PVC/XLPE Isolierseilzug 450/750V, 600/1000V

1*16+16+4*0,5mm2 1/0,8mm PE-Isolat XLPE isoliertes konzentrisches Kabel, Airdac-Kabel

600/1000V, XLPE isoliert, PVC ummantelt, 3X300+150 mm2, XLPE isoliertes Aluminiumkern-Netzkabel

600/1000V, Power Cable, XLPE Insulated, PVC Sheath, 4X50mm2

6mm2 10mm2 16mm2 Airdac konzentrisches Kabel 600/1000V

Popular Aluminum Cable Produkte

  • No related articles
  • Popular Triplex Aluminium Service Drop Cable Produkte

  • No related articles
  • Tags: , , , , ,

    SCHNELLER UND ZUVERLÄSSIGER SERVICE FÜR IHR PROJEKT

    Wenden Sie sich noch heute an unsere geschulten Experten, um Ihre perfekte Stromversorgungslösung zu finden.

    STELLE EINE FRAGE