25kv 35kv Primary Ud Cable Trxlp Insulation

China 
                                 25kv 35kv Primary Ud Cable Trxlp Insulation                              Herstellung und Lieferant

25kv 35kv Primary Ud Cable Trxlp Insulation image

Get Latest Price Request a quote

Basis Info

Modell Nr..
UD cable BM20

Anwendung
U-Bahn

Spannung
Nieder-und Mittelspannung Kabel

Strom
DC & AC

Isoliermaterial
XLPE

Mantelmaterial
PVC

Material Form
Runddraht

Draht Kernmaterial
Blanken Kupferdraht

Bescheinigung
ISO ,
CCC ,
CE ,
RoHS ,
UL ,
VDE

Modell
YJV

Zusätzliche Informationen.

Warenzeichen
Yifang Cable

Verpackung
Wooden or Wooden-Steel Drum

Standard
15 25 35kv

Herkunft
Zhengzhou, China

HS-Code
8544601200

Produktionskapazität
300km/Month

Produktbeschreibung

This 25,000 Volt Primary underground distribution cable comes with your choice of compressed stranded soft drawn copper or a solid or moisture-blocked unilay compressed stranded or reverse lay 1350-H16/26 aluminum phase conductor.  Insulation level options with the conductor are 100% or 133%.  The insulation on this cable is a semi-conducting cross-linked polyethylene strand shield, a tree-retardant cross-linked polyethylene primary insulation, and a semi-conducting cross-linked polyethylene insulation shield.  A layer of concentric neutral bare copper wires is wrapped around the insulation shield, then a sunlight resistant low-density polyethylene jacket which creates the exterior shell of the cable.

25kV Primary UD Cable TRXLP Insulation Polyethylene Jacket Aluminum or Copper Conductors cable is intended for primary underground distribution.  The cable is typically installed in conduit systems, but can be used for installation by direct burial, underground duct, and where exposed to sunlight.  25kV Primary UD Cable TRXLP Insulation Polyethylene Jacket Aluminum or Copper Conductors cable is usable in wet or dry locations and in temperatures as low as -40°C.  With a high durability and resistance to Mother Nature's punishment, this cable is a preferred cable in harsh climates such as tropical regions or arid desert regions.  

 

35kV Primary UD Cable TRXLP Insulation Polyethylene Jacket Aluminum or Copper Conductors cable is designed to transmit underground distribution voltages and comes with your choice of compressed stranded soft drawn copper or a solid or moisture blocked unilay compressed stranded or reverse lay 1350-H16/26 aluminum phase conductor.  Insulation level options with the conductor are 100% or 133%.  The insulation on this cable is a semi-conducting cross-linked polyethylene strand shield, a tree-retardant cross-linked polyethylene primary insulation, and a semi-conducting cross-linked polyethylene insulation shield. Concentric neutral bare copper wires is coiled around the insulation shield, then a low density insulating polyethylene jacket that is sunlight resistant creates the outer jacket of the cable.

 

 

The 35kV Primary UD Cable is intended for primary underground distribution of 35,000 Volts or less.  The cable is typically installed in conduit systems, but can be used for installation by direct burial, underground duct, and where exposed to sunlight.  The cable is usable in wet or dry locations and in temperatures as low as    -40°C.  With a high durability and resistance to Mother Nature's punishment, this cable is a preferred cable in harsh climates such as tropical regions or arid desert regions.  

 

APPLICATIONS

Predominantly used for primary underground distribution in conduit systems; suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 35,000 volts or less and at conductor temperatures not to exceed 90°C for normal operation.

 

SPECIFICATIONS

35kV Primary UD TRXLPE Cable meets or exceeds the following ASTM specifications:

•     B3   Soft Annealed Copper Wire

•     B8   Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft

•     B230       Aluminum, 1350-H19 Wire for Electrical Purposes

•     B231       Aluminum 1350 Conductors, Concentric-Lay-Stranded

•     B609       Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes

 

35kV Primary UD TRXLPE Cable is manufactured to the latest edition of the following specifications, and in case of specification conflicts, in the order listed:

•     ANSI/ICEA S-94-649

•     AEIC CS-8

•     UL1072, When Specified

•     RUS U-1

 

CONSTRUCTION

The cable is composed of a solid or moisture blocked reverse lay, compressed stranded soft drawn copper, or a solid or moisture blocked reverse lay or unilay compressed stranded 1350-H16/26 aluminum phase conductor, covered by a semi-conducting cross-linked polyethylene strand shield, a tree-retardant cross-linked polyethylene primary insulation, and a semi-conducting cross-linked polyethylene insulation shield. Conductors are available with either 100% or 133% insulation levels. A concentric neutral of bare copper wires and a sunlight resistant, -40°C rated, insulating linear low density polyethylene jacket are applied over the insulation shield. The cable is identified by surface print on the jacket and with the lightning bolt symbol for supply cables indented in the jacket. Red extruded stripes available upon request. A semi-conducting polyethylene jacket is also available upon request.

 

 TECHNICAL PARAMETER LIST

 

 

Phase Conductor

 

 

Neutral

 

Thickness Per Cond. (mils)

 

 

Diameter (mils)

 

Weight

1000 feet

(lbs.)

 

Allowable

Ampacities+

 

Size (AWG or kcmil)

 

 

Strand- ing

 

 

No. of

Wires

 

 

Size

(AWG)

 

 

Nominal

Insul.

 

Insul. Shield min. Point

 

 

Approx. Jkt.

 

Bare Phase Cond.

 

 

Over

Insul.

 

Over Insul. Shield

 

 

Comp. Cable

 

 

Comp. Cable

 

 

Direct

Burial

 

 

In

Ducts

ALUMINUM CONDUCTOR – 0.345" INSULATION – 100% INSULATION LEVEL

1/0

Solid

16

14

345

40

50

325

1060

1160

1388

867

209*

149*

1/0

19

16

14

345

40

50

352

1085

1185

1413

889

209*

149*

2/0

19

20

14

345

40

50

395

1130

1230

1458

995

237*

171*

3/0

19

25

14

345

40

50

443

1175

1275

1503

1118

270*

187*

4/0

19

20

12

345

40

50

498

1230

1330

1592

1314

308*

220*

250

37

16

10

345

40

80

558

1300

1400

1758

1619

341*

242*

350

37

18

14

345

40

80

661

1405

1505

1787

1447

384**

323**

500

37

25

14

345

40

80

789

1530

1630

1912

1771

463**

389**

750

61

24

12

345

55

80

968

1720

1850

2166

2412

565**

483**

1000

61

20

10

345

55

80

1117

1868

1998

2355

2983

645**

550**

1250

91

25

10

345

55

80

1250

2013

2143

2500

3512

692**

609**

1500

91

30

10

345

55

80

1370

2133

2263

2620

4240

731**

644**

COPPER CONDUCTOR – 0.345" INSULATION – 100% INSULATION LEVEL

1/0

Solid

25

14

345

40

50

325

1060

1160

1388

1198

262*

186*

1/0

19

25

14

345

40

50

362

1095

1195

1423

1234

262*

186*

2/0

19

20

12

345

40

50

405

1140

1240

1502

1463

300*

215*

3/0

19

25

12

345

40

50

456

1190

1290

1552

1702

340*

238*

4/0

19

20

10

345

40

50

512

1245

1345

1649

2052

389*

276*

250

37

24

10

345

40

80

558

1300

1400

1758

2399

430*

305*

350

37

18

12

345

40

80

661

1405

1505

1821

2365

485**

406**

500

37

26

12

345

40

80

789

1530

1630

1946

3082

573**

480**

750

61

25

10

345

55

80

968

1720

1850

2208

4382

675**

574**

1000

61

26

9

345

55

80

1117

1868

1998

2380

5558

729**

642**

1250

91

26

8

345

55

80

1250

2013

2143

2553

6778

769**

677**

+  Ampacities shown assume use of 100% load factor, 60 Hz current, 36" burial depth, 20°C ambient temperature, 90°C

conductor temperature, earth RHO 90, insulation and shield RHO 400

*   Full neutral construction (Ampacities assume – single phase circuit, one cable)

** 1/3 neutral cable (Ampacities assume – three phase circuit, 3 cables triplexed, multi-point grounding per ICEA methods)

 

Wer wir sind China 25kv 35kv Primary Ud Cable Trxlp Insulation Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.

Get Latest Price Request a quote

Popular 25kv 35kv Primary Ud Cable Trxlp Insulation Produkte

  • No related articles
  • Popular 25kv Ud Cable Produkte

  • No related articles
  • Popular 35kv Ud Cable Produkte

  • No related articles
  • Popular yifangcable Produkte

    Niedriges Volatge Kurbelgehäuse-Belüftung oder XLPE Isolierenergien-Kabel

    Triplex (2+1) Service Drop Aluminium Conductor Cable

    ACSR 50/8mm2 Standard Iec-61089

    R02V U1000 4X16sqmm kupferner Leiter

    U-1000 Arvfv 3X50sqmm+35sqmm

    33kv S/C kupfernes XLPE Energien-Kabel 1X630mm2

    Tags: , , ,

    SCHNELLER UND ZUVERLÄSSIGER SERVICE FÜR IHR PROJEKT

    Wenden Sie sich noch heute an unsere geschulten Experten, um Ihre perfekte Stromversorgungslösung zu finden.

    STELLE EINE FRAGE