300V 14/2 12/2 10/2 8/3 Nmd90 Cable for Canada Market
300V 14/2 12/2 10/2 8/3 Nmd90 Cable for Canada Market image
Get Latest Price Request a quote
Grundlegende Informationen.
Produktbeschreibung
NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations. The maximum allowable conductor temperature is 90°C. The minimum recommended installation temperature is -25°C for two-conductor cables and -10°C for three-conductor cables (with suitable handling procedures). Material should be properly stored above 0°C for 24 hours prior to installation. The maximum voltage rating for all intended applications is 300 volts. Consult the Canadian Electrical Code1 for further information related to applications
Standards:
• ASTM
• CSA C22.2 No. 48 (non-metallic sheathed cable)
• Canadian Electrical Code
CONSTRUCTION:
Conductors:
Solid 14-10 AWG soft, uncoated copper, per ASTM-B3
Stranded 8 AWG conductor and larger uncoated, copper ASTM-B8
Insulation:
Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90°C in dry locations.
Grounding Conductor:
Soft, uncoated copper per ASTM-B3 and/or ASTM-B8
Jacket:
A 30-mil, color-coded, PVC jacket is applied over the completed assembly as follows:
14 AWG White I 12 AWG Yellow I 10 AWG Orange I 8 AWG Black I 6 AWG Black
specification.
Size (AWG) | Number of Strands |
Ground Wire Size |
Insulation Thickness (in) |
Allowable Ampacity (Amps)* |
Outside Diameter (in) |
Approximate Net Weight (lbs/1000 ft) |
|
PVC | Nylon | ||||||
14/2 G | Solid | 14 | 0.015 | 0.004 | 15 | 0.170 x 0.390 | 56 |
12/2 G | Solid | 12 | 0.015 | 0.004 | 20 | 0.160 x 0.450 | 82 |
10/2 G | Solid | 10 | 0.020 | 0.004 | 30 | 0.210 x 0.493 | 123 |
8/2 G | 7 | 10 | 0.030 | 0.005 | 40 | 0.290 x 0.580 | 185 |
6/2 G | 7 | 10 | 0.030 | 0.005 | 55 | 0.330 x 0.695 | 256 |
14/3 G | Solid | 14 | 0.015 | 0.004 | 15 | 0.170 x 0.450 | 74 |
12/3 G | Solid | 12 | 0.015 | 0.004 | 20 | 0.345 | 107 |
10/3 G | Solid | 10 | 0.020 | 0.004 | 30 | 0.430 | 165 |
8/3 G | 7 | 10 | 0.030 | 0.005 | 40 | 0.555 | 251 |
6/3 G | 7 | 10 | 0.030 | 0.005 | 55 | 0.612 | 352 |
4/3 G | 7 | 8 | 0.040 | 0.006 | 70 | 0.820 | 565 |
2/3 G | 7 | 8 | 0.040 | 0.006 | 95 | 0.945 | 841 |
**14/4 G & 14/2-2 G | Solid | 14 | 0.015 | 0.004 | 12 | 0.345 | 90 |
**12/4 G & 12/2-2 G | Solid | 12 | 0.015 | 0.004 | 16 | 0.385 | 132 |
**10/4 G | Solid | 10 | 0.020 | 0.004 | 30 | 0.540 | 205 |
Wer wir sind China 300V 14/2 12/2 10/2 8/3 Nmd90 Cable for Canada Market Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.
Get Latest Price Request a quote
Popular 14/2 Nmd90 Cable Produkte
Popular 300V 14/2 12/2 10/2 8/3 Nmd90 Cable for Canada Market Produkte
Popular huatongcables Produkte
600 V Xhhw/Xhw-2 Incore Serviceeingang Elektrokabel Mit Konzentrischem Leiter
Leiter-konzentrisches Kabel-Service-Eingangs-Kabel der Aluminiumlegierung-UL854 aufgeführter AA-8000
SHD-GC 25kV Tragbares Gummikabel für Mine
Kupferleiter, Gummiisoliertes Elektrisches Schweißkabel
UL-gelistet 14/2 12/2 NMB Wire WG Kupferleiterhaus Nicht Metallisch Ummanteltes Kabel
Popular Nmd90 Cable Produkte
Nmd90 Building Residential Wire Cable Romex 300V C-S-a cUL UL Grounded Receptacles
Building Residential Nmd90 300V Copper Wire Cable 14AWG 12AWG 10AWG 8AWG
with Earth Cable 300V PVC or XLPE/PVC Nmd90 Nylon Electrical Residential Wire Cable 2core 3core
Nmd90 14/2 CSA Certified Electirc Cable 150m/Roll 300V Canada Building Wire
Nmd90 Copper Conductor 300V -25 Degree 90 Degree PVC/Nylon Insulation PVC Jacket Outlet Wiring
Tags: 14/2 Nmd90 Cable, 300V 14/2 12/2 10/2 8/3 Nmd90 Cable for Canada Market, huatongcables, Nmd90 Cable