En50228-7 LSZH Twisted Pair Individual & Overall Screened Instrumentation Cables
En50228-7 LSZH Twisted Pair Individual & Overall Screened Instrumentation Cables image
Get Latest Price Request a quote
Grundlegende Informationen.
Produktbeschreibung
APPLICATION
En50228-7 LSZH sheathed cables are generally use for indoor installation and suitable for wet and damp areas.
The galvanized steel wire armour provides excellent protection. Generally, the cables are used within industrial
process manufacturing plants for communication, data and voice transmission signals and services. Also used for
the interconnection of electrical equipmentand instruments, the LSZH sheath can reduce toxic smoke and fume
emission.
STANDARDS
Basic design to EN 50288-7
FIRE PERFORMANCE
Flame Retardance (Single Vertical Wire Test) | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation(Vertically-mounted bundled wires & cable test)*** | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1;CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2;CEI 20-37/2-2 ; BS 6425-2* |
Minimum Smoke Emission | IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2;CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases | NES 02-713; NF C 20-454 |
Sunlight Resistance | UL 1581 section 1200 |
Oil Resistance** | ICEA S-73-532 |
Note: Asterisk * denotes superseded standard, ** denotes Test temperature +60°C, duration 4h. Retention: min 60% of tensile strength/min.60% of elongation, *** denotes optional.
VOLTAGE RATING
500V
Construction:
1. Conductor Cu conductor of the category 1 according to IEC 60228
2. Insulation XLPE
3. Cable core cores are twisted in pairs, pairs are laid up into cable core
4. Bedding none
5. Screening wrapping by Al/PET foil + CuSn drain wire
6. Sheath fire retardant halogen-free polymer compound
Mechanical and Electrical Properties
Rated voltage: 500 V AC
Testing voltage between cores: 2000 V
Testing voltage between core and screening: 750 V
Insulation resistance: > 1000 MΩ.km
Surrounding temperatures (fixed placement): – 40°C up to + 90°C
Surrounding temperatures (during installation): -5°C up to +50°C
Minimum bending radius (fixed placement): 10D
Cable Design Parameters
RE-2X(St)H PiMF | ||||
No. of Pairs x2xCross Section | Nominal Insulation Thickness | Nominal Outer Sheath Thickness | Nominal Overall Diameter | Approx. Weight |
No.x2xmm2 | mm | mm | mm | kg/km |
0.5mm2, Multipair | ||||
2x2x0.5 | 0.35 | 0.9 | 8.7 | 85 |
4x2x0.5 | 0.35 | 1.0 | 10.2 | 120 |
5x2x0.5 | 0.35 | 1.0 | 11.2 | 145 |
6x2x0.5 | 0.35 | 1.0 | 12.1 | 170 |
8x2x0.5 | 0.35 | 1.1 | 13.1 | 214 |
10x2x0.5 | 0.35 | 1.2 | 15.1 | 265 |
12x2x0.5 | 0.35 | 1.2 | 15.7 | 286 |
16x2x0.5 | 0.35 | 1.2 | 17.8 | 380 |
20x2x0.5 | 0.35 | 1.3 | 19.7 | 475 |
24x2x0.5 | 0.35 | 1.4 | 21.5 | 561 |
0.75mm2, Multipair | ||||
2x2x0.75 | 0.38 | 1.0 | 9.7 | 101 |
3x2x0.75 | 0.38 | 1.0 | 11.2 | 159 |
4x2x0.75 | 0.38 | 1.1 | 12.5 | 183 |
5x2x0.75 | 0.38 | 1.1 | 13.6 | 215 |
8x2x0.75 | 0.38 | 1.1 | 14.4 | 272 |
10x2x0.75 | 0.38 | 1.2 | 16.6 | 333 |
12x2x0.75 | 0.38 | 1.2 | 17.4 | 383 |
16x2x0.75 | 0.38 | 1.3 | 19.8 | 492 |
20x2x0.75 | 0.38 | 1.4 | 22.0 | 603 |
24x2x0.75 | 0.38 | 1.5 | 24.0 | 704 |
1.0mm2, Multipair | ||||
2x2x1.0 | 0.4 | 1.0 | 10.4 | 112 |
3x2x1.0 | 0.4 | 1.0 | 12.1 | 179 |
4x2x1.0 | 0.4 | 1.1 | 13.5 | 220 |
5x2x1.0 | 0.4 | 1.1 | 14.7 | 256 |
8x2x1.0 | 0.4 | 1.2 | 15.8 | 323 |
10x2x1.0 | 0.4 | 1.2 | 18.0 | 401 |
12x2x1.0 | 0.4 | 1.3 | 19.0 | 454 |
16x2x1.0 | 0.4 | 1.3 | 21.5 | 601 |
20x2x1.0 | 0.4 | 1.4 | 23.9 | 719 |
24x2x1.0 | 0.4 | 1.5 | 26.1 | 884 |
1.3mm2, Multipair | ||||
2x2x1.3 | 0.45 | 1.0 | 11.4 | 153 |
3x2x1.3 | 0.45 | 1.1 | 13.4 | 208 |
4x2x1.3 | 0.45 | 1.1 | 14.8 | 263 |
5x2x1.3 | 0.45 | 1.2 | 16.3 | 318 |
8x2x1.3 | 0.45 | 1.3 | 17.6 | 406 |
10x2x1.3 | 0.45 | 1.3 | 20.0 | 501 |
12x2x1.3 | 0.45 | 1.4 | 21.1 | 552 |
16x2x1.3 | 0.45 | 1.5 | 24.1 | 728 |
20x2x1.3 | 0.45 | 1.6 | 26.8 | 892 |
24x2x1.3 | 0.45 | 1.7 | 29.2 | 1067 |
1.5mm2, Multipair | ||||
2x2x1.5 | 0.45 | 1.0 | 11.8 | 164 |
3x2x1.5 | 0.45 | 1.1 | 13.9 | 235 |
4x2x1.5 | 0.45 | 1.2 | 15.5 | 289 |
5x2x1.5 | 0.45 | 1.2 | 16.9 | 366 |
8x2x1.5 | 0.45 | 1.3 | 18.2 | 446 |
10x2x1.5 | 0.45 | 1.4 | 21.0 | 565 |
12x2x1.5 | 0.45 | 1.4 | 21.9 | 637 |
16x2x1.5 | 0.45 | 1.5 | 25.1 | 828 |
20x2x1.5 | 0.45 | 1.6 | 27.8 | 1024 |
24x2x1.5 | 0.45 | 1.7 | 30.4 | 1219 |
Note : Other conductor sizes & core configurations are available upon request
Packing shipping
Wer wir sind China En50228-7 LSZH Twisted Pair Individual & Overall Screened Instrumentation Cables Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.
Get Latest Price Request a quote
Popular En50228-7 Produkte
Popular En50228-7 Instrumentation Cables Produkte
Popular En50228-7 LSZH Twisted Pair Individual & Overall Screened Instrumentation Cables Produkte
Popular zzhongdacable Produkte
4-4-4 Vassar Triplex Aluminum Conductor Underground Direct Burial 600V Urd Cable
Mittleres der Spannungs-50mm2 3c des Cu-XLPE Kabel 133% SWA Belüftung-15kv Bil
6-6-6 Patella Aluminium Triplex-Überkopfkabel Mit Anschlusskabel
KABEL ABC-Luftbündel-Kabel Millivolt-33kv 3X150+50 Sqmm Unkosten Isolier
Flugplatz-Beleuchtungssystem-Gerät5kv 6mm2 XLPE BT Belüftung-Kabel
Leitfähigkeit 21% 30% 40% IACS CCS Kupfer plattiert Stahl Litze Erdungsdraht
Tags: En50228-7, En50228-7 Instrumentation Cables, En50228-7 LSZH Twisted Pair Individual & Overall Screened Instrumentation Cables, zzhongdacable