APPLICATION
En50228-7 LSZH sheathed cables are generally use for indoor installation and suitable for wet and damp areas.
The galvanized steel wire armour provides excellent protection. Generally, the cables are used within industrial
process manufacturing plants for communication, data and voice transmission signals and services. Also used for
the interconnection of electrical equipmentand instruments, the LSZH sheath can reduce toxic smoke and fume
emission.
STANDARDS
Basic design to EN 50288-7
FIRE PERFORMANCE
Flame Retardance (Single Vertical Wire Test) | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation(Vertically-mounted bundled wires & cable test)*** | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1;CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2;CEI 20-37/2-2 ; BS 6425-2* |
Minimum Smoke Emission | IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2;CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases | NES 02-713; NF C 20-454 |
Sunlight Resistance | UL 1581 section 1200 |
Oil Resistance** | ICEA S-73-532 |
Note: Asterisk * denotes superseded standard, ** denotes Test temperature +60°C, duration 4h. Retention: min 60% of tensile strength/min.60% of elongation, *** denotes optional.
VOLTAGE RATING
500V
Construction:
1. Conductor Cu conductor of the category 1 according to IEC 60228
2. Insulation XLPE
3. Cable core cores are twisted in pairs, pairs are laid up into cable core
4. Bedding none
5. Screening wrapping by Al/PET foil + CuSn drain wire
6. Sheath fire retardant halogen-free polymer compound
Mechanical and Electrical Properties
Rated voltage: 500 V AC
Testing voltage between cores: 2000 V
Testing voltage between core and screening: 750 V
Insulation resistance: > 1000 MΩ.km
Surrounding temperatures (fixed placement): – 40°C up to + 90°C
Surrounding temperatures (during installation): -5°C up to +50°C
Minimum bending radius (fixed placement): 10D
Cable Design Parameters
RE-2X(St)H PiMF | ||||
No. of Pairs x2xCross Section | Nominal Insulation Thickness | Nominal Outer Sheath Thickness | Nominal Overall Diameter | Approx. Weight |
No.x2xmm2 | mm | mm | mm | kg/km |
0.5mm2, Multipair | ||||
2x2x0.5 | 0.35 | 0.9 | 8.7 | 85 |
4x2x0.5 | 0.35 | 1.0 | 10.2 | 120 |
5x2x0.5 | 0.35 | 1.0 | 11.2 | 145 |
6x2x0.5 | 0.35 | 1.0 | 12.1 | 170 |
8x2x0.5 | 0.35 | 1.1 | 13.1 | 214 |
10x2x0.5 | 0.35 | 1.2 | 15.1 | 265 |
12x2x0.5 | 0.35 | 1.2 | 15.7 | 286 |
16x2x0.5 | 0.35 | 1.2 | 17.8 | 380 |
20x2x0.5 | 0.35 | 1.3 | 19.7 | 475 |
24x2x0.5 | 0.35 | 1.4 | 21.5 | 561 |
0.75mm2, Multipair | ||||
2x2x0.75 | 0.38 | 1.0 | 9.7 | 101 |
3x2x0.75 | 0.38 | 1.0 | 11.2 | 159 |
4x2x0.75 | 0.38 | 1.1 | 12.5 | 183 |
5x2x0.75 | 0.38 | 1.1 | 13.6 | 215 |
8x2x0.75 | 0.38 | 1.1 | 14.4 | 272 |
10x2x0.75 | 0.38 | 1.2 | 16.6 | 333 |
12x2x0.75 | 0.38 | 1.2 | 17.4 | 383 |
16x2x0.75 | 0.38 | 1.3 | 19.8 | 492 |
20x2x0.75 | 0.38 | 1.4 | 22.0 | 603 |
24x2x0.75 | 0.38 | 1.5 | 24.0 | 704 |
1.0mm2, Multipair | ||||
2x2x1.0 | 0.4 | 1.0 | 10.4 | 112 |
3x2x1.0 | 0.4 | 1.0 | 12.1 | 179 |
4x2x1.0 | 0.4 | 1.1 | 13.5 | 220 |
5x2x1.0 | 0.4 | 1.1 | 14.7 | 256 |
8x2x1.0 | 0.4 | 1.2 | 15.8 | 323 |
10x2x1.0 | 0.4 | 1.2 | 18.0 | 401 |
12x2x1.0 | 0.4 | 1.3 | 19.0 | 454 |
16x2x1.0 | 0.4 | 1.3 | 21.5 | 601 |
20x2x1.0 | 0.4 | 1.4 | 23.9 | 719 |
24x2x1.0 | 0.4 | 1.5 | 26.1 | 884 |
1.3mm2, Multipair | ||||
2x2x1.3 | 0.45 | 1.0 | 11.4 | 153 |
3x2x1.3 | 0.45 | 1.1 | 13.4 | 208 |
4x2x1.3 | 0.45 | 1.1 | 14.8 | 263 |
5x2x1.3 | 0.45 | 1.2 | 16.3 | 318 |
8x2x1.3 | 0.45 | 1.3 | 17.6 | 406 |
10x2x1.3 | 0.45 | 1.3 | 20.0 | 501 |
12x2x1.3 | 0.45 | 1.4 | 21.1 | 552 |
16x2x1.3 | 0.45 | 1.5 | 24.1 | 728 |
20x2x1.3 | 0.45 | 1.6 | 26.8 | 892 |
24x2x1.3 | 0.45 | 1.7 | 29.2 | 1067 |
1.5mm2, Multipair | ||||
2x2x1.5 | 0.45 | 1.0 | 11.8 | 164 |
3x2x1.5 | 0.45 | 1.1 | 13.9 | 235 |
4x2x1.5 | 0.45 | 1.2 | 15.5 | 289 |
5x2x1.5 | 0.45 | 1.2 | 16.9 | 366 |
8x2x1.5 | 0.45 | 1.3 | 18.2 | 446 |
10x2x1.5 | 0.45 | 1.4 | 21.0 | 565 |
12x2x1.5 | 0.45 | 1.4 | 21.9 | 637 |
16x2x1.5 | 0.45 | 1.5 | 25.1 | 828 |
20x2x1.5 | 0.45 | 1.6 | 27.8 | 1024 |
24x2x1.5 | 0.45 | 1.7 | 30.4 | 1219 |
Note : Other conductor sizes & core configurations are available upon request
Packing shipping
Wer wir sind China Type a B C En50228-7 Cable LSZH 1 2 3 5 6 Pair 0.75mm2 Screened Instrumentation Cables Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.
Get Latest Price Request a quote
Popular 0.75mm2 Cable Produkte
Popular En50228-7 Cable Produkte
Popular Type a B C En50228-7 Cable LSZH 1 2 3 5 6 Pair 0.75mm2 Screened Instrumentation Cables Produkte
Popular zzhongdacable Produkte
Aluminium-Plattiertes obenliegendes Erdungsdraht Alumoweld Stahlkabel 7#8 7#9
NFC 33209 Aluminium-Leiter XLPE Insulation Twist 3*95+54,6+25sqmm Overhead ABC Antennenkabel
- 60-180c AGR Silikon-Gummi-flexibler Draht-/Kabel-Doppeltes Isolierfeuer-Hochtemperaturbeweis
NFC 33 209 Twist Overhead Line Aluminium Torsadkabel 3X35+1X16+1X54, 6 mm2
Typen von einphasigen Multicore 300mm XLPE SWA PVC Underground Gepanzertes Netzkabel
Einadriger 6~30AWG Kupferleiter PVC-Erdungsdraht
Tags: 0.75mm2 Cable, En50228-7 Cable, Type a B C En50228-7 Cable LSZH 1 2 3 5 6 Pair 0.75mm2 Screened Instrumentation Cables, zzhongdacable