Hvdc Mv Hv 33kv Submarine Power Cable Transmission Cable Transmission System Operators

China 
                Hvdc Mv Hv 33kv Submarine Power Cable Transmission Cable Transmission System Operators
              Herstellung und Lieferant

Hvdc Mv Hv 33kv Submarine Power Cable Transmission Cable Transmission System Operators image

Get Latest Price Request a quote

Grundlegende Informationen.

Modell Nr.
Submarine Power Cable

Draht Kernmaterial
Blanken Kupferdraht

Bescheinigung
ISO, CCC

Modell
ZRYJV22

Marke
Low, Medium, High Voltage

Core No
1, 2, 3, 4, 5, 3+1, 4+1, 3+2

Standard
GB/T 12706-2008, IEC 60502-2005

Sheath Color
Black or as Request

Screen
Copper Tape, Copper Wire

Armor Material
Galvanized Steel Wire, Steel Tape, Copper Tape

Popular Size
50mm, 95mm, 120mm, 150mm

Related Voltage
0.6/1kv, 8.7/15kv, 12/20kv, 21-35kv, 36kv

OEM
Yes

Business Type
Factory

Transportpaket
Steel-Wooden Drum or as Request

Spezifikation
0.5-800mm2

Warenzeichen
KINGYEAR

Herkunft
Henan, China

HS-Code
8544492100

Produktionskapazität
500km/Month

Produktbeschreibung

HVDC MV HV 33KV Submarine Power Cable Transmission Cable Transmission System Operators

Standard:

IEC60502, BS6346, VDE, AS/NZS, UL, etc 

The Rated Voltage(kv):

1st  class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35 
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 – 26/35

Application:

XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables. XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level. It can be applied in high temperature of 90 degree for a long time.
PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.

TYPE

NAME

Main Application

CU core

AL core

YJV/YJY

YJLV/YJLY

XLPE insulated,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Unable to bear external mechanical forces,
but bear the traction force during laid

YJV22/YJV23

YJLV22/YJLV23

XLPE insulated,steel tape armored,
PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Able to bear external mechanical forces,
but unable to bear large pulling force

YJV32/YJV33

YJLV32/YJLV33

XLPE insulated,thin steel wire armored,
PVC/PE sheathed power cable

For laying in shaft,water underground will large difference of level.
Able to bear external mechanical forces and moderate pulling force

YJV42/YJV43

YJLV42/YJLV43

XLPE insulated,thick steel wire armored,
PVC/PE sheathed power cable

For laying in water and seabed.
Able to bear positive pressure and pulling force

Number of cores:

1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.

Nominal Section 
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800

Features:

1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.
5).Application: for laying indoor, tunnel, canal and underground. 

Specification

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Alum Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
1×4 2.3 0.7 1 0.8 1.8 10.9
1×6 2.8 0.7 1 0.8 1.8 11.4
1×10 3.6 0.7 1 0.8 1.8 12.2
1×16 4.5 0.7 1 0.8 1.8 13.1
1×25 5.6 0.9 1 0.8 1.8 14.6
1×35 6.7 0.9 1 1.25 1.8 16.6
1×50 8 1 1 1.25 1.8 18.1
1×70 9.4 1.1 1 1.25 1.8 19.7
1×95 11 1.1 1 1.6 1.8 22
1×120 12.4 1.2 1 1.6 1.8 23.6
1×150 13.8 1.4 1 1.6 1.8 25.4
1×185 15.3 1.6 1 1.6 1.8 27.4
1×240 17.5 1.7 1 1.6 1.9 29.9
1×300 19.5 1.8 1 2 2 33.1
1×400 22.6 2 1.2 2 2.2 37.3
1×500 25.2 2.2 1.2 2 2.3 40.5

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
2×1.5 1.4 0.7 1 0.8 1.8 12.8
2×2.5 1.8 0.7 1 0.8 1.8 13.6
2×4 2.3 0.7 1 0.8 1.8 14.6
2×6 2.8 0.7 1 1.25 1.8 16.5
2×10 3.6 0.7 1 1.25 1.8 18.1
2×16 4.5 0.7 1 1.25 1.8 19.9
2×25 5.6 0.9 1 1.6 1.8 23.6
2×35 6.7 0.9 1 1.6 1.8 25.8
2×50 8 1 1 1.6 1.9 29
2×70 9.4 1.1 1 2 2 .3 3.2
2×95 11 1.1 1.2 2.1 3 7.1
2×120 12.4 1.2 1.2 2 2.3 40.5
2×150 13.8 1.4 1.2 2.5 2.4 45.4
2×185 15.3 1.6 1.4 2.5 20.6 49.9
2×240 17.5 1.7 1.4 2.5 20.7 55.1
2×300 19.5 1.8 1.6 2.5 20.9 60.2
2×400 22.6 2 1.6 2.5 30.1 67.7

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
3×1.5 1.4 0.7 1 0.8 1.8 13.2
3×2.5 1.8 0.7 1 0.8 1.8 14.1
3×4 2.3 0.7 1 0.8 1.8 15.2
3×6 2.8 0.7 1 1.25 1.8 17.1
3×10 3.6 0.7 1 1.25 1.8 18.9
3×16 4.5 0.7 1 1.25 1.8 20.8
3×25 5.6 0.9 1 1.6 1.8 24.7
3×35 6.7 0.9 1 1.6 1.8 27.2
3×50 8 1 1 1.6 1.9 30.6
3×70 9.4 1.1 1 2 2.1 35.2
3×95 11 1.1 1.2 2 2.2 39.3
3×120 12.4 1.2 1.2 2 2.3 43
3×150 13.8 1.4 1.4 2.5 2.5 48.6
3×185 15.3 1.6 1.4 2.5 2.7 53
3×240 17.5 1.7 1.4 2.5 2.8 58.5
3×300 19.5 1.8 1.6 2.5 3 64
3×400 22.6 2 1.6 3.15 3.3 73.5

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1 1.6 1.8 22.7
3x 25/16 5.6 4.5 0.9 0.7 1 1.6 1.8 26.5
3x 35/16 6.7 4.5 0.9 0.7 1 1.6 1.9 29
3x 50/25 8 5.6 1 0.9 1 1.6 2.1 33
3x 70/35 9.4 6.7 1.1 0.9 1.2 2 2.2 38
3x 95/50 11 8 1.1 1 1.2 2 2.3 42.4
3×120/70 12.4 9.4 1.2 1.1 1.2 2 2.5 48
3×150/70 13.8 9.4 1.4 1.1 1.4 2.5 2.7 52
3×185/95 15.3 11 1.6 1.1 1.4 2.5 2.8 57.2
3×240/120 17.5 12.4 1.7 1.2 1.6 2.5 3.1 64
3×300/150 19.5 13.8 1.8 1.4 1.6 2.5 3.2 69.8

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
4×1.5 1.4 0.7 1 0.8 1.8 14
4×2.5 1.8 0.7 1 0.8 1.8 14.9
4×4 2.3 0.7 1 1.25 1.8 17
4×6 2.8 0.7 1 1.25 1.8 18.2
4×10 3.6 0.7 1 1.25 1.8 20.2
4×16 4.5 0.7 1 1.6 1.8 23
4×25 5.6 0.9 1 1.6 1.8 26.7
4×35 6.7 0.9 1 1.6 1.9 29.5
4×50 8 1 1 2 2.1 34.2
4×70 9.4 1.1 1.2 2 2.2 38.8
4×95 11 1.1 1.2 2 2.3 42.9
4×120 12.4 1.2 1.4 2.5 2.5 48.6
4×150 13.8 1.4 1.4 2.5 2.7 53.2
4×185 15.3 1.6 1.4 2.5 2.8 58.1
4×240 17.5 1.7 1.6 2.5 3.1 64.8
4×300 19.5 1.8 1.6 2.5 3.2 70.4
4×400 22.6 2 1.8 3.15 3.6 81.3

1). Rated Voltage, No. of Core and Range of Sectional Area

Rated voltage (kv)
Sectional area (mm2)
No. of core
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 26/35
1 Core   1.5-800 25-800 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
2 Core   1.5-185 25-185            
3 Core   1.5-400 25-400 25-400 25-400 35-400 50-400 50-400 50-400
4 Core   2.5-400 25-400            
5 Core   2.5-400 25-400            

 2).  DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.

Nominal section area (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Copper core 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.099 0.0754 0.0601 0.047 0.0366 0.0283 0.0221
Aluminum core 18.1 12.1 7.41 4.61 3.08 1.91 1.2 0.868 0.641 0.443 0.32 0.253 0.206 0.164 0.125 0.1 0.778 0.0605 0.0469 0.0367

 3). Voltage Test and Partial Discharge Test

Rate voltage Uo (kv)
Item
0.6/1 1.8/3 3.6/6 6/6 6/10 8.7/10 8.7/15 12/20 18/20 18/30 21/35 26/35
Voltage Test voltage 3.5 6.5 12.5 21 30.5 42 63 73.5 91
Test time 5 5 5 5 5 5 5 5 5
Partial discharge test Test voltage 6.2 10.4 15.1 20.8 31.1 36.3 45
Discharge capacity 10 10 10 10 10 10 10

Packaging
Packing Details  : Packing in wooden drum, iron-wooden drum or as customer's requirement.
Delivery Details : 15-25 days after place an order.

About Us
Henan Kingyear Aluminum Industrial Co., Ltd was founded in 2006, located in Gongyi industry area of Henan Province. Our company consists of 3 main subsidiaries, business specialized in develop, manufacture and distribution of Aluminum products. Our factories zone occupies more than 1200,000 square meters and the employees' number has exceeded 200.
We, Kingyear, dedicate ourselves to be a manufacturer of providing comprehensive solutions and customized services to help our customer to solve their problems and improve their profit.
We have a professional sales team with each of them has engaged in this job for 10 years, so that we can provide the comprehensive and professional technology for you.
With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!

Our Service:
1.10 years production experience and 10 years export experience .
2.Products certification :ISO,SGS,CE,BV
3.OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback,Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7.Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.

FAQ
Q:I didn't find the product which I need in this page?
A:If you didn't find the species of the produxts you need, please contact us directly, we will reply you quickly.
Q:What's your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 5 tons.
Q:What's your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us, we will send you the free sample, but the freight charge should be paid.
Q:What if the product which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include size, color, material, processing requirement etc.

Just leave your message if you are interested in our products,We will contact you very soon!

—————————————————–
 
 Contact us
 
 

—————————————————–
 

Wer wir sind China Hvdc Mv Hv 33kv Submarine Power Cable Transmission Cable Transmission System Operators Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.

Get Latest Price Request a quote

Popular 3X185mm Armored Power Cable Produkte

  • No related articles
  • Popular Factory Wholesale Price 3core Power Cable Produkte

  • No related articles
  • Popular Hvdc Mv Hv 33kv Submarine Power Cable Transmission Cable Transmission System Operators Produkte

  • No related articles
  • Popular kingyear Produkte

    ASTM JIS Aluminium-Platten-frische Aktien des en-Standard-7020

    Aluminiumaluminiumring des ring-Rollen(3003 8011 1050 1060 1100) für Dosen-Dekoration

    Tausendstel-Ende-cm-Weg 1000 3000 8000 Legierungs-Aluminiumring

    Pflanzendirekt obenliegendes Kraftübertragungentblössen Liniengebrauch 35mm 50mm2 kupfernen Leiter-AAC AAAC ACSR Tacsr Aacsr Acar Aluminium-/blank Aluminiumleiter

    Cu-Leiter XLPE isolierte Stahlband-gepanzertes Energien-Kabel

    6kv 10kv 11kv ABC-Kabel-Hochspannung ABC-Kabel

    Tags: , , ,

    SCHNELLER UND ZUVERLÄSSIGER SERVICE FÜR IHR PROJEKT

    Wenden Sie sich noch heute an unsere geschulten Experten, um Ihre perfekte Stromversorgungslösung zu finden.

    STELLE EINE FRAGE