ABC-Kabel (Mit Antenne Gebündelter Leiter)
ABC-Kabel (Mit Antenne Gebündelter Leiter) image
Get Latest Price Request a quote
Basis Info
Zusätzliche Informationen.
Produktbeschreibung
ABC Cable; Service Drop Cable
The basic construction is as follows:
3 power cores consisting of standard aluminium conductors, insulated with
XLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanised steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.
To be used at cotages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75oC for polyethylene insulated conductors or 90oC for crossliked polyethylene(XLPE) insulated conductors.
Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474Cord word Phase conductor Bare neutral messenger Nominal lay length Weight per 1000ft (ibs) Allowable AMP cities
Cord word Phase conductor Bare neutral messenger Nominal lay length Weight per 1000ft (ibs) Allowable AMP cities
Size
(AWG) Stranding Insul. Thick(Mils) Size
(AWG) Stranding Pated strength(ibs) inches XLPE PE XLPE PE
AAC Neutral-messenger
| Cord word | Phase conductor | Bare neutral messenger | Nominal lay length | Weight per 1000ft (ibs) | Allowable amp cities | |||||||
| Size (AWG) |
Stranding | Insul. Thick(Mils) | Size (AWG) |
Stranding | Pated strength(ibs) | inches | XLPE | PE | XLPE | PE | ||
| AAC Neutral-messenger | ||||||||||||
| Pekingese | 6 | 1 | 45 | 6 | 7 | 563 | 10.36 | 61 | 61 | 85 | 70 | |
| Collie | 6 | 7 | 45 | 6 | 7 | 563 | 10.36 | 64 | 64 | 85 | 70 | |
| Dachshund | 4 | 1 | 45 | 4 | 7 | 881 | 10.36 | 92 | 92 | 115 | 90 | |
| Spaniel | 4 | 7 | 45 | 4 | 7 | 881 | 10.36 | 96 | 96 | 115 | 90 | |
| Doberman | 2 | 7 | 45 | 2 | 7 | 1350 | 14.88 | 147 | 147 | 150 | 120 | |
| Malamute | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 14.88 | 234 | 234 | 205 | 160
|
|
| (1)Self-supporting | |||||||||||
| Phase | Phase | Phase | Approx.Overall Diameter | Min.Bending Radius | Max. D.C. Resistance of Conductor at 20 | ||||||
| AAC+UV-XLPE | Compact Conductor | UV-XLPE Insulation | |||||||||
| No.X Normal Cross Section of Cores | No.of Al Wires | Overall Diameter | Thickness | Min. | Diameter | ||||||
| No. X mm 2 | – | mm | mm | mm | mm | mm | kN | ohm/km | |||
| 4 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 17.42 | 2.07 | 1.91 | |||
| 4 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 21.3 | 3.3 | 1.2 | |||
| 4 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 24.68 | 4.5 | 0.868 | |||
| 4 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 27.83 | 6.2 | 0.641 | |||
| 4 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 32.91 | 8.9 | 0.443 | |||
| 4 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 36.78 | 12.3 | 0.32 | |||
| 4 X 120 | 19 | 13 | 1.8 | 1.52 | 16.6 | 40.17 | 15.6 | 0.253 | |||
| 4 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 44.04 | 19.2 | 0.206 | |||
| 3 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 15.55 | 2.07 | 1.91 | |||
| 3 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 19.01 | 3.3 | 1.2 | |||
| 3 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 22.03 | 4.5 | 0.868 | |||
| 3 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 24.84 | 6.2 | 0.641 | |||
| 3 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 29.38 | 8.9 | 0.443 | |||
| 3 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 32.83 | 12.3 | 0.32 | |||
| 3 X 120 | 19 | 13 | 1.8 | 1.52 | 16.6 | 35.86 | 15.6 | 0.253 | |||
| 3 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 39.31 | 19.2 | 0.206 | |||
| 2 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 14.4 | 2.07 | 1.91 | |||
| 2 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 17.6 | 3.3 | 1.2 | |||
| 2 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 20.4 | 4.5 | 0.868 | |||
| 2 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 23 | 6.2 | 0.641 | |||
| 2 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 27.2 | 8.9 | 0.443 | |||
| 2 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 30.4 | 12.3 | 0.32 | |||
| 2 X 120 | 19 | 13 | 1.8 | 1.52 | 16.6 | 33.2 | 15.6 | 0.253 | |||
| 2 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 36.4 | 19.2 | 0.206 | |||
| 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 7.2 | 2.07 | 1.91 | |||
| 1 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 8.8 | 3.3 | 1.2 | |||
| 1 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 10.2 | 4.5 | 0.868 | |||
| 1 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 11.5 | 6.2 | 0.641 | |||
| 1 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 13.6 | 8.9 | 0.443 | |||
| 1 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 15.2 | 12.3 | 0.32 | |||
| 1 X 120 | 19 | 13.01 | 1.8 | 1.52 | 16.6 | 16.6 | 15.6 | 0.253 | |||
| 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 18.2 | 19.2 | 0.206 | |||
| (2) Phase + Supporting | |||||||||||
| Phase | Supporting | Phase | Supporting | Approx. Overall Diameter | |||||||
| AAC+UV-XLPE | AAAC+UV-XLPE | Compact Conductor | UV-XLPE Insulation | Conductor | UV-XLPE Insulation | ||||||
| No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.of Al Wires | Overall Diameter | Normal Thickness | No./Dia.of Al. Wire | Normal Thickness | |||||
| No. X mm 2 | No. X mm 2 | – | mm | mm | No./mm | mm | mm | ||||
| 3 X 16 | 1 X 54.6 | 7 | 4.8 | 1.2 | 7/3.15 | 1.6 | 20.72 | ||||
| 3 X 25 | 1 X 54.6 | 7 | 6 | 1.4 | 7/3.15 | 1.6 | 23.63 | ||||
| 3 X 35 | 1 X 54.6 | 7 | 7 | 1.6 | 7/3.15 | 1.6 | 26.17 | ||||
| 3 X 50 | 1 X 54.6 | 7 | 8.3 | 1.6 | 7/3.15 | 1.6 | 28.53 | ||||
| 3 X 70 | 1 X 54.6 | 19 | 10 | 1.8 | 7/3.15 | 1.6 | 32.34 | ||||
| 3 X 95 | 1 X 54.6 | 19 | 11.6 | 1.8 | 7/3.15 | 1.6 | 35.24 | ||||
| 3 X 120 | 1 X 54.6 | 19 | 13 | 1.8 | 7/3.15 | 1.6 | 37.78 | ||||
| 3 X 150 | 1 X 54.6 | 19 | 14.6 | 1.8 | 7/3.15 | 1.6 | 40.69 | ||||
| 3 X 16 | 1 X 70 | 7 | 4.8 | 1.2 | 7/3.5 | 1.6 | 21.36 | ||||
| 3 X 25 | 1 X 70 | 7 | 6 | 1.4 | 7/3.5 | 1.6 | 24.26 | ||||
| 3 X 35 | 1 X 70 | 7 | 7 | 1.6 | 7/3.5 | 1.6 | 26.8 | ||||
| 3 X 50 | 1 X 70 | 7 | 8.3 | 1.6 | 7/3.5 | 1.6 | 29.16 | ||||
| 3 X 70 | 1 X 70 | 19 | 10 | 1.8 | 7/3.5 | 1.6 | 32.97 | ||||
| 3 X 95 | 1 X 70 | 19 | 11.6 | 1.8 | 7/3.5 | 1.6 | 35.88 | ||||
| 3 X 120 | 1 X 70 | 19 | 13 | 1.8 | 7/3.5 | 1.6 | 38.42 | ||||
| 3 X 150 | 1 X 70 | 19 | 14.6 | 1.8 | 7/3.5 | 1.6 | 41.32 | ||||
| 3) Phase+Supporting+ Service Connection | |||||||||||
| Phase | Supporting | Service Connection | Phase | Supporting | Service Connection | Approx.Overall Diameter of Bundled Cable | |||||
| AAC+UV-XLPE | AAAC+UV-XLPE | AAC+UV-XLPE | Compact Conductor | UV-XLPE | Conductor | UV-XLPE | Compact Conductor | UV-XLPE | |||
| No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.of Al.Wire | Overall Dia. | Normal | No./Dia.of Al. Wire | Normal | No. of Al. Wire | Overall Dia. | Normal | |
| Thickness | Thickness | Thickness | |||||||||
| No. X mm 2 | No. X mm 2 | No. X mm 2 | – | mm | mm | No./mm | mm | – | mm | mm | mm |
| 3 X 16 | 1 X 54.6 | 1 X 25 | 7 | 4.8 | 1.2 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 27.05 |
| 3 X 25 | 1 X 54.6 | 1 X 25 | 7 | 6 | 1.4 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 30.25 |
| 3 X 35 | 1 X 54.6 | 1 X 25 | 7 | 7 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 33.05 |
| 3 X 50 | 1 X 54.6 | 1 X 25 | 7 | 8.3 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 35.65 |
| 3 X 70 | 1 X 54.6 | 1 X 25 | 19 | 10 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 39.85 |
| 3 X 95 | 1 X 54.6 | 1 X 25 | 19 | 11.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 43.05 |
| 3 X 120 | 1 X 54.6 | 1 X 25 | 19 | 13 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 45.85 |
| 3 X 150 | 1 X 54.6 | 1 X 25 | 19 | 14.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 49.05 |
| 3 X 16 | 1 X 54.6 | 2 X 25 | 7 | 4.8 | 1.2 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 27.05 |
| 3 X 25 | 1 X 54.6 | 2 X 25 | 7 | 6 | 1.4 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 30.25 |
| 3 X 35 | 1 X 54.6 | 2 X 25 | 7 | 7 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 33.05 |
| 3 X 50 | 1 X 54.6 | 2 X 25 | 7 | 8.3 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 35.65 |
| 3 X 70 | 1 X 54.6 | 2 X 25 | 19 | 10 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 39.85 |
| 3 X 95 | 1 X 54.6 | 2 X 25 | 19 | 11.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 43.05 |
| 3 X 120 | 1 X 54.6 | 2 X 25 | 19 | 13 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 45.85 |
| 3 X 150 | 1 X 54.6 | 2 X 25 | 19 | 14.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 49.05 |
Wer wir sind China ABC-Kabel (Mit Antenne Gebündelter Leiter) Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.
Get Latest Price Request a quote
Popular Abc Cable Produkte
Quadruplex Service Drop ACSR Neutralleiter Hackney
Quadruplex Service Drop Cable, ACSR Neutral, Twisted 600 V Quadruplex (ANSI/ICEA S-76-474)
Low Voltage 0.6/1kv ABC Cable for Overhead Use
Triplex Service Drop Cable with ACSR Neutral, Twisted 600 V Triplex (ANSI/ICEA S-76-474)
Aluminum Cable Twisted 7 Cores PE Cable
Hot Saleaerial Bundled Cable, ABC Cable, Overhead Cable, ASTM, BS, NFC, IEC, DIN Standard
Popular ABC-Kabel (Mit Antenne Gebündelter Leiter) Produkte
ABC-Kabel (Mit Antenne Gebündelter Leiter)
Popular Duplex-Service-Drop Produkte
Luftleitbündel, XLPE-Isoliert, 16 mm2
ABC-Kabel 600/1000 V 4c 95 mm ABC-Kabel
Duplex-Service-Drop, ACSR Neutral, 1/0 AWG Heeler
Duplex-Service-Drop, AAAC 6201, Legierung, neutraler Leiter, Heeler
Duplex Service Dropcable, ABC-Kabel 70 mm2
Duplex Drop Wire Bull 1/0AWG+1/0AWG Duplex Service Drop ABC-Kabel
Popular yifangcable Produkte
6/10kv, 11kv 3c300sqmm XLPE gepanzertes Energien-Kabel
336 MCM 795 kcmil 477 MCM ACSR Osprey Conductor Overhead Blanker Leiter 161mm ACSR Tigerdraht
0.6/1 KV 4X240 Cu XLPE Belüftung-doppelte Stahlband-Rüstungs-direktes Beerdigungs-Energien-Kabel-
Unterwasserenergien-Kabel-Kupfer XLPE unterseeisch
70 mm2 Aluminium Sac-Kabelservice-Fallkabel
Kurbelgehäuse-Belüftung 0.6/1kv sah Kabel 4core 16sqmm
Tags: Abc Cable, ABC-Kabel (Mit Antenne Gebündelter Leiter), Duplex-Service-Drop, yifangcable