Aluminum Cable Twisted 7 Cores PE Cable
Aluminum Cable Twisted 7 Cores PE Cable image
Get Latest Price Request a quote
- Überblick
- Specification
- Company Profile
- Our Factory
- Packaging & Shipping
- FAQ
Grundlegende Informationen.
Produktbeschreibung
The cable as a new-type aerial cable is used for transmitting electric power overhead, extensively used in rebuilding of urban and forest region electrified wire netting. It improves the safety and reliance of electrified wire netting.
Specification:
Concentric strand aluminum wires as phase conductor; AAAC(all aluminum alloy conductors) or ACSR(aluminum conductor steel reinforced) as messenger (Neutral) core; Phase conductor is insulated by XLPE or HDPE or PVC.
Standards:
IEC60502, NF C33-209, GB 12527-90
Rated voltage: 0.6/1kV
Relative manufacturing standards: IEC61089, ASTM B231, ASTM B232, BS215, DIN48201, DIN48204.
We can also manufacture ABC cable according to customer's special requirements.
The basic construction is as follows:
3 cores consisting of standard aluminium conductors, insulated with XLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanised steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.
To be used at cotages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75 degree for polyethylene insulated conductors or 90 degree for crossliked polyethylene(XLPE) insulated conductors.
It meets or exceeds the following specifications:
1. Aluminum Wire, 1350-H19 for Electrical Purposes.
2. Aluminum Conductors, Concentric-Lay-Stranded.
3. Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. Concentric-Lay-Stranded 6201-T81 Conductors.
5. Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
It meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
BS 7870-5: Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV
ABC Cables without Street Lighting | ||||||||
1+1 Structure | ||||||||
Phase Conductor | Neutral Conductor | Completed Cable | ||||||
Section | Insulation Thickness | Electrical Resistance | Section | Insulation Thickness | Electrical Resistance | Overall Diameter | Cable Weight | |
DC.20°C | DC.20°C | |||||||
No.xmm2 | mm | Ω/km | mm2 | mm | Ω/km | mm | kg/km | |
1×25 | 1.3 | 1.20 | 25 | 1.3 | 1.20 | 17.6 | 210 | |
1×35 | 1.3 | 0.868 | 35 | 1.3 | 0.868 | 19.6 | 270 | |
1×50 | 1.5 | 0.641 | 50 | 1.5 | 0.641 | 23 | 360 | |
1×70 | 1.5 | 0.443 | 70 | 1.5 | 0.443 | 26.4 | 500 | |
1×95 | 1.7 | 0.320 | 95 | 1.7 | 0.320 | 30.6 | 680 | |
3+1 Structure | ||||||||
Phase Conductor | Neutral Conductor | Completed Cable | ||||||
Section | Insulation Thickness | Electrical Resistance | Section | Insulation Thickness | Electrical Resistance | Overall Diameter | Cable Weight | |
DC.20°C | DC.20°C | |||||||
No.xmm2 | mm | Ω/km | mm2 | mm | Ω/km | mm | kg/km | |
3×25 | 1.3 | 1.20 | 25 | 1.3 | 1.20 | 21.2 | 410 | |
3×35 | 1.3 | 0.868 | 35 | 1.3 | 0.868 | 23.7 | 550 | |
3×50 | 1.5 | 0.641 | 50 | 1.5 | 0.641 | 27.8 | 730 | |
3×70 | 1.5 | 0.443 | 70 | 1.5 | 0.443 | 31.9 | 1000 | |
3×95 | 1.7 | 0.320 | 95 | 1.7 | 0.320 | 36.9 | 1370 | |
3×120 | 1.7 | 0.253 | 120 | 1.7 | 0.253 | 40.6 | 1690 |
Duplex Service Drop-Aluminum Conductor
Code | Phase Conductor | Bare Neutral Messenger | Weight Per | Rating(Amps) | ||||||
Name | 1000 ft(lbs) | |||||||||
Size | Strand | Insulation | Size | *Strand | Breaking | XLPE | POLY | XLPE | POLY | |
AWG | thickness | AWG | strength | |||||||
(MLS) | (lbs) | |||||||||
AAC | ||||||||||
Pekingese | 6 | solid | 45 | 6 | 7/w | 563 | 63.5 | 61.7 | 70 | 70 |
Collie | 6 | 7/w | 45 | 6 | 7/w | 563 | 66.8 | 63.1 | 70 | 70 |
Dachshund | 4 | solid | 45 | 4 | 7/w | 881 | 95.5 | 93.4 | 90 | 90 |
Spaniel | 4 | 7/w | 45 | 4 | 7/w | 881 | 101 | 95.4 | 90 | 90 |
Doberman | 2 | 7/w | 45 | 2 | 7/w | 1,350 | 153 | 145.7 | 120 | 120 |
Malemute | 1/0 | 19/w | 60 | 1/0 | 7/w | 1,990 | 243 | 234.2 | 160 | 160 |
ACSR NEUTRAL-MESSENGER | ||||||||||
Setter | 6 | solid | 45 | 6 | '6/1 | 1.19 | 75 | 73.2 | 70 | 70 |
Shepherd | 6 | 7/w | 45 | 6 | '6/2 | 1.19 | 78.3 | 74.6 | 70 | 70 |
Eskimo | 4 | solid | 45 | 4 | '6/3 | 1.86 | 114 | 111.6 | 90 | 90 |
Terrier | 4 | 7/w | 45 | 4 | '6/4 | 1.86 | 119 | 113.6 | 90 | 90 |
Chow | 2 | 7/w | 45 | 2 | '6/5 | 2.85 | 182 | 174.7 | 120 | 120 |
Bull | 1/0 | 19/w | 60 | 1/0 | '6/6 | 4.38 | 289 | 280.3 | 160 | 160 |
6201 ALLOY NEUTRAL-MESSENGER | ||||||||||
Chihuahua | 6 | solid | 45 | 6 | 7/w | 1,110 | 67.6 | 65.8 | 70 | 70 |
Vizsla | 6 | 7/w | 45 | 6 | 7/w | 1,110 | 70.9 | 67.2 | 70 | 70 |
Harrier | 4 | solid | 45 | 4 | 7/w | 1,760 | 102 | 99.9 | 90 | 90 |
Whippet | 4 | 7/w | 45 | 4 | 7/w | 1,760 | 107 | 101.9 | 90 | 90 |
Schnauzer | 2 | 7/w | 45 | 2 | 7/w | 2,800 | 163 | 156.2 | 120 | 120 |
Heeler | 1/0 | 19/w | 60 | 1/0 | 7/w | 4,460 | 259 | 250.8 | 160 | 160 |
Triplex Service Drop-Aluminum Conductor
Code | Phase Conductor | Bare Neutral Messenger | Weight Per | Ampacity (Amps) | |||||||
Name | 1000 ft(lbs) | ||||||||||
Size | Stranding | Insulation | Size | Stranding | Breaking | XLPE | POLY | XLPE | POLY | ||
AWG | thickness | AWG | strength | ||||||||
(MLS) | (lbs) | ||||||||||
6201 ALLOY NEUTRAL-MESSENGER | |||||||||||
Minex | 6 | solid | 45 | 6 | 7 | 1,110 | 106.6 | 102.9 | 85 | 70 | |
Hippa | 6 | 7/w | 45 | 6 | 7 | 1,110 | 113.2 | 105.7 | 85 | 70 | |
Prawn | 4 | solid | 45 | 4 | 7 | 1,760 | 158.4 | 154.1 | 115 | 90 | |
Barnacles | 4 | 7/w | 45 | 4 | 7 | 1,760 | 168.3 | 158.2 | 115 | 90 | |
Shrimp | 2 | 7/w | 45 | 2 | 7 | 2,800 | 253.7 | 239.7 | 150 | 120 | |
Gammarus | 1/0 | 7/w | 60 | 1/0 | 7 | 4,460 | 411.7 | 386 | 205 | 160 | |
Leda | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 402.7 | 386 | 205 | 160 | |
Dungenese | 2/0 | 7/w | 60 | 2/0 | 7 | 5,390 | 506.8 | 476.3 | 235 | 185 | |
Cyclops | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 495.3 | 476.3 | 235 | 185 | |
Flustra | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 611.4 | 589.1 | 275 | 215 | |
Lepas | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 757.1 | 730.5 | 315 | 245 | |
6201 ALLOY REDUCED NEUTRAL-MESSENGER | |||||||||||
Artemia | 4 | solid | 45 | 6 | 7 | 1,110 | 141.4 | 137.1 | 115 | 90 | |
Crab | 4 | 7/w | 45 | 6 | 7 | 1,110 | 151.3 | 141.2 | 115 | 90 | |
Solaster | 2 | 7/w | 45 | 4 | 7 | 1,760 | 226.6 | 212.6 | 150 | 120 | |
Sandcrab | 1/0 | 7/w | 60 | 2 | 7 | 2,800 | 368.8 | 343.1 | 205 | 160 | |
Echinus | 1/0 | 19/w | 60 | 2 | 7 | 2,800 | 358.8 | 343.1 | 205 | 160 | |
Crayfish | 2/0 | 7/w | 60 | 1 | 7 | 3,530 | 452.6 | 422.5 | 235 | 185 | |
Sipho | 2/0 | 19/w | 60 | 1 | 7 | 3,530 | 441 | 422.5 | 235 | 185 | |
Fulgar | 3/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 543.4 | 521.1 | 275 | 215 | |
Arca | 4/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 671.2 | 644.6 | 315 | 245 | |
AAC NEUTRAL-MESSENGER | |||||||||||
Haiotis | 6 | solid | 45 | 6 | 7 | 563 | 102.5 | 98.8 | 85 | 70 | |
Patella | 6 | 7/w | 45 | 6 | 7 | 563 | 109.1 | 101.6 | 85 | 70 | |
Fusus | 4 | solid | 45 | 4 | 7 | 881 | 151.9 | 147.6 | 115 | 90 | |
Oyster | 4 | 7/w | 45 | 4 | 7 | 881 | 161.8 | 151.7 | 115 | 90 | |
Clam | 2 | 7/w | 45 | 2 | 7 | 1,350 | 243.2 | 229.2 | 150 | 120 | |
Murex | 1/0 | 7/w | 60 | 1/0 | 7 | 1,990 | 395.1 | 369.4 | 205 | 160 | |
Purpura | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 386.1 | 369.4 | 205 | 160 | |
Nassa | 2/0 | 7/w | 60 | 2/0 | 7 | 2,510 | 485.8 | 455.3 | 235 | 185 | |
Melita | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 585.2 | 562.9 | 275 | 215 | |
Portunus | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 723.9 | 697.3 | 315 | 245 | |
Nannynose | 336.4 | 19/w | 80 | 336 | 19 | 6,146 | 1160 | 1118 | 420 | 325 | |
WITH FULL SIZE ACSR MESSENGER | |||||||||||
Paludina | 6 | solid | 45 | 6 | '6/1 | 1,190 | 114 | 113 | 85 | 70 | |
Voluta | 6 | 7/w | 45 | 6 | '6/1 | 1,190 | 120 | 113 | 85 | 70 | |
Whelk | 4 | solid | 45 | 4 | '6/1 | 1,860 | 169 | 165 | 115 | 90 | |
Periwinkle | 4 | 7/w | 45 | 4 | '6/1 | 1,860 | 176 | 172 | 115 | 90 | |
Conch | 2 | 7/w | 45 | 2 | '6/1 | 2,850 | 267 | 261 | 150 | 120 | |
Neritina | 1/0 | 7/w | 60 | 1/0 | '6/1 | 4,380 | 530 | 419 | 205 | 160 | |
Cenia | 1/0 | 19/w | 60 | 1/0 | '6/1 | 4,380 | 426 | 416 | 205 | 160 | |
Runcina | 2/0 | 7/w | 60 | 2/0 | '6/1 | 5,310 | 530 | 519 | 235 | 185 | |
Triton | 2/0 | 19/w | 60 | 2/0 | '6/1 | 5,310 | 526 | 514 | 235 | 185 | |
Cherrystone | 3/0 | 7/w | 60 | 3/0 | '6/1 | 6,620 | 656 | 643 | 250 | 200 | |
Mursia | 3/0 | 19/w | 60 | 3/0 | '6/1 | 6,620 | 650 | 638 | 250 | 200 | |
Razor | 4/0 | 7/w | 60 | 4/0 | '6/1 | 8,350 | 814 | 799 | 315 | 245 | |
Zuzara | 4/0 | 19/w | 60 | 4/0 | '6/1 | 8,350 | 805 | 792 | 315 | 245 | |
Limpet | 336.4 | 19/w | 80 | 336 | '6/1 | 8,680 | 1209 | 1167 | 420 | 325 | |
WITH ACSR REDUCED SIZE MESSENGER | |||||||||||
Scallop | 4 | Solid | 45 | 6 | '6/1 | 1,190 | 148 | 144 | 115 | 90 | |
Strombus | 4 | 7/w | 45 | 6 | '6/1 | 1,190 | 158 | 148 | 115 | 90 | |
Cockle | 2 | 7/ w | 45 | 4 | '6/1 | 1,860 | 233 | 227 | 150 | 120 | |
Janthina | 1/0 | 7/ w | 60 | 2 | '6/1 | 2,850 | 376 | 365 | 205 | 160 | |
Ranella | 1/0 | 19/ w | 60 | 2 | '6/1 | 2,850 | 372 | 362 | 205 | 160 |
Quadruplex Service Drop-Aluminum Conductor
Code | Phase Conductor | Bare Neutral Messenger | Weight Per | Rating(Amps) | ||||||
Name | 1000 ft(lbs) | |||||||||
Size | Strand | Insulation | Size | Strand | Breaking | XLP | POLY | XLP | POLY | |
AWG | thickness | AWG | strength | |||||||
(MLS) | (lbs) | |||||||||
AAC NEUTRAL-MESSENGER | ||||||||||
Clydesdale | 4 | Solid | 45 | 4 | 7 | 881 | 208 | 201.8 | 100 | 80 |
Pinto | 4 | 7/w | 45 | 4 | 7 | 881 | 223 | 207.9 | 100 | 80 |
Mustang | 2 | 7/w | 45 | 2 | 7 | 1,350 | 333 | 312.6 | 135 | 105 |
Criollo | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 529 | 504.5 | 180 | 140 |
Percheron | 2/0 | 19/w | 60 | 2/0 | 7 | 2,510 | 649 | 620.5 | 205 | 160 |
Hanoverian | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 799 | 765.6 | 235 | 185 |
Oldenburg | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 986 | 946.7 | 275 | 210 |
Lippizaner | 336.4 | 19/w | 80 | 336.4 | 19 | 6,146 | 1,546 | 1,519.20 | 370 | 280 |
ACSR NEUTRAL-MESSNGER | ||||||||||
Morochuca | 6 | Solid | 45 | 6 | '6/1 | 1,190 | 152 | 147.4 | 75 | 60 |
Chola | 6 | 7/w | 45 | 6 | '6/1 | 1,190 | 162 | 151.7 | 75 | 60 |
Morgan | 4 | Solid | 45 | 4 | '6/1 | 1,860 | 226 | 220 | 100 | 80 |
Hackney | 4 | 7/w | 45 | 4 | '6/1 | 1,860 | 241 | 226.1 | 100 | 80 |
Palomino | 2 | 7/w | 45 | 2 | '6/1 | 2,850 | 362 | 342.6 | 135 | 105 |
Costena | 1/0 | 19/w | 60 | 1/0 | '6/1 | 4,380 | 575 | 550.6 | 180 | 140 |
Grullo | 2/0 | 19/w | 60 | 2/0 | '6/1 | 5,310 | 707 | 678.7 | 205 | 160 |
Suffolk | 3/0 | 19/w | 60 | 3/0 | '6/1 | 6,620 | 872 | 838.9 | 235 | 185 |
Appaloosa | 4/0 | 19/w | 60 | 4/0 | '6/1 | 8,350 | 1079 | 1039.2 | 275 | 210 |
Bronco | 336.4 | 19/w | 80 | 336.4 | '18/1 | 8,580 | 1613 | 1568.2 | 370 | 280 |
Gelding | 336.4 | 19/w | 80 | 4/0 | '6/1 | 8,350 | 1548 | 1494.3 | 370 | 280 |
6201 ALLOY NEUTRAL-MESSENGER | ||||||||||
Bay | 6 | Solid | 45 | 6 | 7 | 1,110 | 145 | 140 | 75 | 60 |
French Coach | 6 | 7/w | 45 | 6 | 7 | 1,110 | 155 | 144.3 | 75 | 60 |
German Coach | 4 | Solid | 45 | 4 | 7 | 1,760 | 214 | 208.3 | 100 | 80 |
Arabian | 4 | 7/w | 45 | 4 | 7 | 1,760 | 229 | 214.4 | 100 | 80 |
Belgian | 2 | 7/w | 45 | 2 | 7 | 2,800 | 344 | 323.1 | 135 | 105 |
Shetland | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 546 | 521.1 | 180 | 140 |
Thoroughbred | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 670 | 641.5 | 205 | 160 |
Trotter | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 825 | 791.8 | 235 | 185 |
Walking | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 1019 | 979.7 | 275 | 210 |
6201 ALLOY NEUTRAL-MESSENGER | ||||||||||
Code Name | Phase Conductor | Bare Neutral Messenger | Weight Per 1000ft(lbs) | Rating(Amps) | ||||||
Size AWG | Strand | Insulation Thickness(mls) | Size AWG | Strand | Breaking Strength(lbs) | XLPE | Poly | XLPE | Poly | |
Bay | 6 | Solid | 45 | 6 | 7 | 1,110 | 145 | 140.0 | 75 | 60 |
French Coach | 6 | 7/w | 45 | 6 | 7 | 1,110 | 155 | 144.3 | 75 | 60 |
German Coach | 4 | Solid | 45 | 4 | 7 | 1,760 | 214 | 208.3 | 100 | 80 |
Arabian | 4 | 7/w | 45 | 4 | 7 | 1,760 | 229 | 214.4 | 100 | 80 |
Belgian | 2 | 7/w | 45 | 2 | 7 | 2,800 | 344 | 323.1 | 135 | 105 |
Shetland | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 546 | 521.1 | 180 | 140 |
Thoroughbred | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 670 | 641.5 | 205 | 160 |
Trotter | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 825 | 791.8 | 235 | 185 |
Walking | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 1,019 | 979.7 | 275 | 210 |
https://jsgroup.en..com/product-list-1.html
Zhengzhou Jinshui Industry & Commerce Co.Ltd is located in the national class Zhengzhou high and new technology industries zone in Zhengzhou ,Henan province. We have owned a number of exclusive essential manufacture technologies and has pass ISO 9001 Quality Management Systerm, ISO 14001 Environmental Management Systerm, OHSAS18001 occupational Heath Management Systerm, ISO 10012 Measurement Management Systerm and others from China and abroad.
We have been engaged in producing electric cable and wire for nearly 20 years, and we are also 12 year gold supplier. And we are confident that we can offer the best service and quality for you.
Our product range is as following:
*Bare conductors(AAC, AAAC, ACSR, Galvanized steel wire)
*Aerial Bounded Cable (Duplex, Triplex,Quadruplex)
* PVC insulated wire (Rated voltage to 450/750V)
*THHN/THWN wire
*PVC insulated Power Cable
*XLPE insulated Power Cable
*Rubber sheathed Cable
*Control Cable
*Welding Cable
*Cable AccessoriesWe take part in many fairs and exhibitions in China and abroad. Our aim is to be our customer's factory in Zhengzhou, China .
We are here to help you placing orders of cost-effective electric cable and keep tracking your products and shipment.
1.Professional production lines, experienced workers, ensure the production of every thing is fine and accurate.
2.We choose excellent raw materials carefully to ensure the quality and meet the need of customers.
3.Mechanical testing of Cables is done to determine the quality and mechanical characteristics before delivery.
(1). Are you the factory or trading company?
We are the manufacturer and 18 years gold supplier on Made in China. We are engaged in exporting cables for nearly 20 years.
(2).When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
(3).How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
(4). What is the payment terms?
30% deposit by T/T,70% T/T after before shipment.
(5).What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.
Welcome your kind enquiry!!!
Wer wir sind China Aluminum Cable Twisted 7 Cores PE Cable Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.
Get Latest Price Request a quote
Popular Abc Cable Produkte
0.6/1 Kv Low Voltage Overhead Aluminum AAC AAAC Conductor Cable XLPE Insulated Aluminium Cable
Hot Selling Cable Aluminium Core XLPE Insulation ABC Cable
Hot Sales 15kv Overhead ABC Cable
XLPE Insulated ABC Cable with Aluminum Core Industrial Cable
Quadruplex Service Drop ACSR Neutralleiter Hackney
Duplex Service Dropcable, ABC-Kabel 70 mm2
Popular Aluminum Cable Twisted 7 Cores PE Cable Produkte
Popular jsgroup Produkte
185mm 500 mm2 33kV Cu/ XLPE Aluminium-Koaxialkabel
Flexibles PVC-Mehrcore-Steuerkabel 450/750V
ASTM Duplex Service Cable (ABC-KABEL) für Overhead-Anwendungen
AAAC-Leiter ACSR Bare Overhead Conductor
10-500 Quadratmm Kabel für niedrige und mittlere Spannung, blanker Überkopfleiter
ABC Kabel Overhead elektrische Übertragungsleitung Holzpaket