Direct Manufacturer Supply ACSR Conductor BS Standard

China 
                                 Direct Manufacturer Supply ACSR Conductor BS Standard                              Herstellung und Lieferant

Direct Manufacturer Supply ACSR Conductor BS Standard image

Get Latest Price Request a quote

Basis Info

Modell Nr..
ACSR

Art
Blank

Leitertyp
Stranded

Anwendung
Oben

Leitermaterial
Aluminium

Material Form
Runddraht

Bescheinigung
ISO9001 ,
CE

Zusätzliche Informationen.

Warenzeichen
JIAPU

Verpackung
Wooden Drum

Standard
Aluminum Conductor Steel Reinforecd

Herkunft
Zhengzhou China

HS-Code
7614900000

Produktionskapazität
1000km/ Day

Produktbeschreibung

ACSR Conductor

(1). All aluminium conductor (AAC)
(2). All aluminimum alloy conductor(AAAC)
(3). Aluminum conductor steel reinforced (ACSR)
(4). Anti-corrosion type ACSR
(5). Aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6). Rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7). Aluminimum conductor aluminimum alloy reinforced(ACAR)

Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191

AAC(All aluminum conductor) are suited for overhead power line.

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.

ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.

Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.

Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

Property
Aluminum 1350 wires are concentrically stranded and wrapped helically around a central wire. Each successive layer has six wires more than the previous underlying layer. Outer layer is right hand lay and reversed in successive layers.

Standard:

ASTM B230,B231,B400 Standard

Code word Size of
Conductor
Stranding and Wire Diameter Overall Diameter Max.D.C. Resistance at 20°C Code word Size of Conductor Stranding and Wire Diameter Overall Diameter Max.D.C. Resistance at 20°C
AWG or MCM mm mm ohm/km AWG or MCM mm mm ohm/km
Peachbell 6 7/1.554 4.67 2.1692 Verbena 700 37/3.493 24.45 0.0813
Rose 4 7/1.961 5.89 1.3624 Nasturtium 715.5 61/2.75 24.76 0.0795
Lris 2 7/2.474 7.42 0.8577 Violet 715.5 37/3.533 24.74 0.0795
Pansey 1 7/2.776 8.33 0.6801 Cattail 750 61/2.817 25.35 0.0759
Poppy 1/0 7/3.119 9.36 0.5390 Petunia 750 37/3.617 25.32 0.0759
Aster 2/0 7/3.503 10.51 0.4276 Lilac 795 61/2.90 26.11 0.0715
Phlox 3/0 7/3.932 11.80 0.3390 Arbutus 795 37/3.724 26.06 0.0715
Oxlip 4/0 7/4.417 13.26 0.2688 Snapdragon 900 61/3.086 27.78 0.0632
Valerian 250 19/2.913 14.57 0.2275 Cockscomb 900 37/3.962 27.73 0.0632
Sneezewort 250 7/4.80 14.4 0.2275 Goldenrod 954 61/3.177 28.6 0.0596
Laurel 266.8 19/3.01 15.05 0.2133 Magnolia 954 37/4.079 28.55 0.0596
Daisy 266.8 7/4.96 14.9 0.2133 Camellia 1000 61/3.251 29.36 0.0569
Peony 300 19/3.193 15.97 0.1896 Hawkweed 1000 37/4.176 29.23 0.0569
Tulip 336.4 19/3.381 16.91 0.1691 Larkspur 1033.5 61/3.307 29.76 0.0550
Daffodil 350 19/3.447 17.24 0.1625 Bluebell 1033.5 37/4.244 29.72 0.0550
Canna 397.5 19/3.673 18.36 0.1431 Marigold 1113 61/3.432 30.89 0.0511
Goldentuft 450 19/3.909 19.55 0.1264 Hawthorn 1192.5 61/3.551 31.05 0.0477
Syringa 477 37/2.882 20.19 0.1193 Narcissus 1272 61/3.668 33.02 0.0477
Cosmos 477 19/4.023 20.12 0.1193 Columbine 1351.5 61/3.78 34.01 0.0421
Hyacinth 500 37/2.951 20.65 0.1138 Carnation 1431 61/3.89 35.03 0.0398
Zinnia 500 19/4.12 20.6 0.1138 Gladiolus 1510.5 61/4.00 35.09 0.0376
Dahlia 556.5 19/4.346 21.73 0.1022 Coreopsis 1590 61/4.099 36.51 0.03568
Mistletoe 556.5 37/3.114 21.79 0.1022 Jessamine 1750 61/4.302 38.72 0.0325
Meadowsweet 600 37/3.233 22.63 0.0948 Cowslip 2000 91/3.76 41.40 0.02866
Orchid 636 37/3.33 23.31 0.0894 Lupine 2500 91/4.21 46.30 0.0230
Heuchera 650 37/3.366 23.56 0.0875 Trillium 3000 127/3.90 50.75 0.0192
Flag 700 61/2.72 24.48 0.0813 Bluebonnet 3500 127/4.21 54.80 0.01653

Wer wir sind China Direct Manufacturer Supply ACSR Conductor BS Standard Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.

Get Latest Price Request a quote

Popular acsr Produkte

Alu-Leiter Stahl Verstärkt Blanke Litze ACSR

Aluminiumleiter-plattierter Aluminiumstahl verstärken Draht ACSR

Aluminiumleiter des leiter-Stahl verstärkter blank Aluminiumkabel-ACSR

Konkurrenzfähiger Preis AAC, AAAC, ACSR, ACSR/Aw, Accc, Aacsr, Acar Unkosten angeschwemmter blank Leiter

ACSR/Aw Aluminiumleiter, Aluminium-Plattierter Stahl verstärktes Größen-Kabel

Alu-Leiter Stahl Verstärkt ACSR

Popular acsr bs standard Produkte

ACSR BS Standardstrang-Aluminiumrotwild-Code-elektrischer Draht

Popular Direct Manufacturer Supply ACSR Conductor BS Standard Produkte

  • No related articles
  • Popular jpcable99 Produkte

    Hochleistungs--mittleres Spannungs-XLPE Unarmoured Energien-Isolierkabel

    XLPE kupfernes 20kv oder Aluminiumisolierkabel

    Copper Core Medium Voltage XLPE Insulated Power Cable

    Kurbelgehäuse-Belüftung Isolierdraht 2.5mm2

    ACSR mit BS215 Standard

    Flint & Greely AAAC blanker Leiter

    Tags: , , ,

    SCHNELLER UND ZUVERLÄSSIGER SERVICE FÜR IHR PROJEKT

    Wenden Sie sich noch heute an unsere geschulten Experten, um Ihre perfekte Stromversorgungslösung zu finden.

    STELLE EINE FRAGE