Hochwertiges Kabel für das ABC-Antennenbündel mit 33 kv Mittelspannung
Hochwertiges Kabel für das ABC-Antennenbündel mit 33 kv Mittelspannung image
Get Latest Price Request a quote
Basis Info
Oben ,
Industriell ,
Kraftwerk
CCC ,
CE ,
UL
Zusätzliche Informationen.
Produktbeschreibung
Aluminium Secondary UD Cable
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR.One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1.B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2.B-231 Aluminum conductors, Concentric-Lay-Stranded.
3.B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4.B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5.B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6.Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1.Rated Voltage:0.6/1kV
2.Cable installation temperature not less than -20°C
3.Max. temperature of cable at short circuit(The max. duration does not exceed 5 minutes)
For XLPE insulation is 250°C.
For HDPE insulation is 150 °C.
4.The Max. bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1.Duplex Service Drop:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
2.Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
3.Quadruplex Service Drop: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
ASTM B-230, B-231 and ICEA S-66-524
UL Standard 854 for type USE
Federal Specification JC-30B NEC
Code Name | Phase Conductor | Neutral | Single Phase Conductor(in) | Outside diameter(in) | Weight Per 1000ft (lbls) | Ampacity | |||||
Size AWG | Strand | Insulation Thickness (mls) | Size AWG | Strand | Insulation Thickness (mls) | Direct Burial | In Duct | ||||
Tulsa | 4 | 7/w | 60 | 4 | 7/w | 60 | .345 | .833 | 258 | 119 | 85 |
Dyke | 2 | 7/w | 60 | 4 | 7/w | 60 | .403 | .938 | 346 | 153 | 115 |
Wittenberg | 2 | 7/w | 60 | 2 | 7/w | 60 | .403 | .973 | 375 | 153 | 115 |
Notre Dame | 1/0 | 19/w | 80 | 2 | 7/w | 60 | .522 | 1.188 | 541 | 198 | 150 |
Purdue | 1/0 | 19/w | 80 | 1/0 | 19/w | 80 | .522 | 1.260 | 596 | 198 | 150 |
Syracuse | 2/0 | 19/w | 80 | 1/0 | 19/w | 80 | .566 | 1.316 | 664 | 225 | 170 |
Lafayette | 2/0 | 19/w | 80 | 2/0 | 19/w | 80 | .566 | 1.367 | 720 | 225 | 170 |
Swarthmore | 3/0 | 19/w | 80 | 1/0 | 19/w | 80 | .616 | 1.430 | 805 | 250 | 195 |
Davidson | 3/0 | 19/w | 80 | 3/0 | 19/w | 80 | .616 | 1.487 | 874 | 250 | 195 |
Wake Forest | 4/0 | 19/w | 80 | 2/0 | 19/w | 80 | .672 | 1.560 | 979 | 290 | 225 |
Earlham | 4/0 | 19/w | 80 | 4/0 | 19/w | 80 | .672 | 1.623 | 1066 | 290 | 225 |
Slippery Rock | 350 | 37/w | 95 | 4/0 | 19/w | 80 | .851 | 1.945 | 1544 | 385 | 305 |
Wofford | 500 | 37/w | 95 | 350 | 37/w | 95 | .851 | 2.348 | 2174 | 467 | 420 |
Windham | 750 | 61/w | 110 | 500 | 37/w | 95 | .979 | 2.850 | 2542 | 615 | 492 |
Wer wir sind China Hochwertiges Kabel für das ABC-Antennenbündel mit 33 kv Mittelspannung Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.
Get Latest Price Request a quote
Popular 33kv Service Drop Produkte
Popular ABC Produkte
Aluminiumleiter Stahl Verstärkt, ACSR-Leiter
Overhead-Isoliertes Antennenbündel Service Drop Triplex ABC-Kabel mit Hoher Qualität
KABEL VORMONTIERTER ALUMINIUMleiter 2X25mm2 XLPE ISOLIER0.6/1kv
ABC-Kabel montieren vor und aerien torsade basse Spannkraft 3X70+54,6+2X16mm2 0.6/1kV
Luftgröße 4X35 des bündel-Kabel-(ABC-Kabel mit XLPE Isolierung)
600V XLPE- oder PE-Überkopfkabel 25 mm2, 35 mm2, 50 mm2, ABC-Kabel
Popular Hochwertiges Kabel für das ABC-Antennenbündel mit 33 kv Mittelspannung Produkte
Popular huatongcable Produkte
Aluminiumbeschichteter Stahlleiter IEC 61089/ASTM B416/DIN 48201
Korrosionsschutz-Schmierfett ACSR-Leiter mit Hoher Qualität
PV1f PV-Solarkabel, TUV, Verzinnt, gemäß UL, 6 mm2
ABC-Kabel 1X25 1X35 1X50 1X70 1X95 1X120 Erdungskabel
Quadruplex-Leiter aus Aluminiumleiter, 600 V, sekundäres Ursulenkabel
Tags: 33kv Service Drop, ABC, Hochwertiges Kabel für das ABC-Antennenbündel mit 33 kv Mittelspannung, huatongcable