Hot Seller Medium Voltage XLPE Insulated Unarmoured Power Cable
Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Prpperty:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Specification:
Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.
1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | ||
| Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||||
| mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
| 25 | 6.0 | 2.5 | 0.12 | 1.5 | 17.6 | 0.34 | 0.49 | 1.2000 | 0.7270 |
| 35 | 7.0 | 2.5 | 0.12 | 1.5 | 18.5 | 0.39 | 0.60 | 0.8680 | 0.5240 |
| 50 | 8.3 | 2.5 | 0.12 | 1.6 | 20.0 | 0.46 | 0.74 | 0.6410 | 0.3870 |
| 70 | 9.7 | 2.5 | 0.12 | 1.6 | 21.5 | 0.55 | 0.96 | 0.4430 | 0.2680 |
| 95 | 11.3 | 2.5 | 0.12 | 1.7 | 23.3 | 0.66 | 1.23 | 0.3200 | 0.1930 |
| 120 | 13 | 2.5 | 0.12 | 1.7 | 24.8 | 0.77 | 1.48 | 0.2530 | 0.1530 |
| 150 | 14.6 | 2.5 | 0.12 | 1.8 | 26.4 | 0.87 | 1.77 | 0.2060 | 0.1240 |
| 185 | 15.9 | 2.5 | 0.12 | 1.8 | 28.1 | 1.01 | 2.13 | 0.1640 | 0.0991 |
| 240 | 18.3 | 2.6 | 0.12 | 1.9 | 30.9 | 1.23 | 2.71 | 0.1250 | 0.0754 |
| 300 | 20.4 | 2.8 | 0.12 | 2.0 | 33.6 | 1.48 | 3.32 | 0.1000 | 0.0601 |
| 400 | 23.2 | 3.0 | 0.12 | 2.1 | 37.0 | 1.81 | 4.16 | 0.0778 | 0.0470 |
| 500 | 26.4 | 3.2 | 0.12 | 2.2 | 41.1 | 2.24 | 5.27 | 0.0605 | 0.0366 |
| 630 | 30.1 | 3.2 | 0.12 | 2.3 | 45.0 | 2.73 | 6.62 | 0.0469 | 0.0283 |
2)6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | |||
| Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||||
| mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km | |
| 25 | 6.0 | 3.4 | 0.12 | 1.5 | 19.4 | 0.40 | 0.55 | 1.2000 | 0.7270 | |
| 35 | 6.9 | 3.4 | 0.12 | 1.6 | 20.5 | 0.45 | 0.66 | 0.8680 | 0.5240 | |
| 50 | 8.2 | 3.4 | 0.12 | 1.6 | 21.8 | 0.52 | 0.80 | 0.6410 | 0.3870 | |
| 70 | 9.7 | 3.4 | 0.12 | 1.7 | 23.5 | 0.62 | 1.03 | 0.4430 | 0.2680 | |
| 95 | 11.3 | 3.4 | 0.12 | 1.7 | 25.1 | 0.73 | 1.30 | 0.3200 | 0.1930 | |
| 120 | 12.8 | 3.4 | 0.12 | 1.8 | 26.8 | 0.85 | 1.56 | 0.2530 | 0.1530 | |
| 150 | 14.2 | 3.4 | 0.12 | 1.8 | 28.2 | 0.95 | 1.85 | 0.2060 | 0.1240 | |
| 185 | 15.9 | 3.4 | 0.12 | 1.9 | 30.1 | 1.10 | 2.22 | 0.1640 | 0.0991 | |
| 240 | 18.3 | 3.4 | 0.12 | 2.0 | 32.7 | 1.33 | 2.80 | 0.1250 | 0.0754 | |
| 300 | 20.4 | 3.4 | 0.12 | 2.0 | 34.8 | 1.54 | 3.39 | 0.1000 | 0.0601 | |
| 400 | 23.2 | 3.4 | 0.12 | 2.2 | 38.0 | 1.87 | 4.22 | 0.0778 | 0.0470 | |
| 500 | 26.4 | 3.4 | 0.12 | 2.2 | 41.5 | 2.26 | 5.29 | 0.0605 | 0.0366 | |
| 630 | 30.1 | 3.4 | 0.12 | 2.4 | 45.6 | 2.78 | 6.67 | 0.0469 | 0.0283 | |
3)8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | |||
| Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||||
| mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km | |
| 25 | 6.0 | 4.5 | 0.12 | 1.6 | 21.8 | 0.48 | 0.63 | 1.2000 | 0.7270 | |
| 35 | 6.9 | 4.5 | 0.12 | 1.7 | 22.9 | 0.54 | 0.75 | 0.8680 | 0.5240 | |
| 50 | 8.2 | 4.5 | 0.12 | 1.7 | 24.2 | 0.61 | 0.89 | 0.6410 | 0.3870 | |
| 70 | 9.7 | 4.5 | 0.12 | 1.8 | 25.9 | 0.72 | 1.13 | 0.4430 | 0.2680 | |
| 95 | 11.3 | 4.5 | 0.12 | 1.8 | 27.5 | 0.84 | 1.40 | 0.3200 | 0.1930 | |
| 120 | 12.8 | 4.5 | 0.12 | 1.9 | 29.2 | 0.96 | 1.67 | 0.2530 | 0.1530 | |
| 150 | 14.2 | 4.5 | 0.12 | 1.9 | 30.6 | 1.06 | 1.96 | 0.2060 | 0.1240 | |
| 185 | 15.9 | 4.5 | 0.12 | 2.0 | 32.5 | 1.22 | 2.34 | 0.1640 | 0.0991 | |
| 240 | 18.3 | 4.5 | 0.12 | 2.1 | 35.1 | 1.46 | 2.93 | 0.1250 | 0.0754 | |
| 300 | 20.4 | 4.5 | 0.12 | 2.1 | 37.2 | 1.68 | 3.52 | 0.1000 | 0.0601 | |
| 400 | 23.2 | 4.5 | 0.12 | 2.2 | 40.2 | 2.00 | 4.35 | 0.0778 | 0.0470 | |
| 500 | 26.4 | 4.5 | 0.12 | 2.3 | 43.9 | 2.43 | 5.45 | 0.0605 | 0.0366 | |
| 630 | 30.1 | 4.5 | 0.12 | 2.4 | 47.8 | 2.93 | 6.83 | 0.0469 | 0.0283 | |
4)12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | ||
| Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||||
| mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
| 25 | |||||||||
| 35 | 6.9 | 5.5 | 0.12 | 1.7 | 24.9 | 0.62 | 0.83 | 0.8680 | 0.5240 |
| 50 | 8.2 | 5.5 | 0.12 | 1.8 | 26.4 | 0.70 | 0.98 | 0.6410 | 0.3870 |
| 70 | 9.7 | 5.5 | 0.12 | 1.8 | 27.9 | 0.80 | 1.21 | 0.4430 | 0.2680 |
| 95 | 11.3 | 5.5 | 0.12 | 1.9 | 29.7 | 0.94 | 1.50 | 0.3200 | 0.1930 |
| 120 | 12.8 | 5.5 | 0.12 | 1.9 | 31.2 | 1.05 | 1.77 | 0.2530 | 0.1530 |
| 150 | 14.2 | 5.5 | 0.12 | 2.0 | 32.8 | 1.17 | 2.07 | 0.2060 | 0.1240 |
| 185 | 15.9 | 5.5 | 0.12 | 2.0 | 34.5 | 1.33 | 2.45 | 0.1640 | 0.0991 |
| 240 | 18.3 | 5.5 | 0.12 | 2.1 | 37.1 | 1.57 | 3.04 | 0.1250 | 0.0754 |
| 300 | 20.4 | 5.5 | 0.12 | 2.2 | 39.4 | 1.81 | 3.66 | 0.1000 | 0.0601 |
| 400 | 23.2 | 5.5 | 0.12 | 2.3 | 42.4 | 2.14 | 4.49 | 0.0778 | 0.0470 |
| 500 | 26.4 | 5.5 | 0.12 | 2.4 | 46.1 | 2.58 | 5.61 | 0.0605 | 0.0366 |
| 630 | 30.1 | 5.5 | 0.12 | 2.4 | 49.8 | 3.10 | 6.99 | 0.0469 | 0.0283 |
5)18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | |||
| Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||||
| mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km | |
| 25 | ||||||||||
| 35 | ||||||||||
| 50 | 8.2 | 8.0 | 0.12 | 2.0 | 31.8 | 0.95 | 1.23 | 0.6410 | 0.3870 | |
| 70 | 9.7 | 8.0 | 0.12 | 2.0 | 33.3 | 1.07 | 1.47 | 0.4430 | 0.2680 | |
| 95 | 11.3 | 8.0 | 0.12 | 2.1 | 35.1 | 1.21 | 1.78 | 0.3200 | 0.1930 | |
| 120 | 12.8 | 8.0 | 0.12 | 2.1 | 36.6 | 1.34 | 2.05 | 0.2530 | 0.1530 | |
| 150 | 14.2 | 8.0 | 0.12 | 2.2 | 38.2 | 1.47 | 2.37 | 0.2060 | 0.1240 | |
| 185 | 15.9 | 8.0 | 0.12 | 2.2 | 39.9 | 1.64 | 2.76 | 0.1640 | 0.0991 | |
| 240 | 18.3 | 8.0 | 0.12 | 2.3 | 42.5 | 1.90 | 3.37 | 0.1250 | 0.0754 | |
| 300 | 20.4 | 8.0 | 0.12 | 2.4 | 44.8 | 2.16 | 4.01 | 0.1000 | 0.0601 | |
| 400 | 23.2 | 8.0 | 0.12 | 2.4 | 47.6 | 2.52 | 4.87 | 0.0778 | 0.0470 | |
| 500 | 26.4 | 8.0 | 0.12 | 2.5 | 51.3 | 2.98 | 6.01 | 0.0605 | 0.0366 | |
| 630 | 30.1 | 8.0 | 0.12 | 2.6 | 55.2 | 3.54 | 7.43 | 0.0469 | 0.0283 | |
6)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | ||||
| Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||||||
| mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km | ||
| 25 | 6.0 | 2.5 | 0.1 | 2.0 | 34.6 | 1.13 | 1.58 | 1.2000 | 0.7270 | ||
| 35 | 6.9 | 2.5 | 0.1 | 2.1 | 36.8 | 1.29 | 1.92 | 0.8680 | 0.5240 | ||
| 50 | 8.2 | 2.5 | 0.1 | 2.2 | 39.8 | 1.51 | 2.36 | 0.6410 | 0.3870 | ||
| 70 | 9.7 | 2.5 | 0.1 | 2.3 | 43.2 | 1.81 | 3.04 | 0.4430 | 0.2680 | ||
| 95 | 11.3 | 2.5 | 0.1 | 2.4 | 46.9 | 2.17 | 3.87 | 0.3200 | 0.1930 | ||
| 120 | 12.8 | 2.5 | 0.1 | 2.4 | 50.1 | 2.53 | 4.69 | 0.2530 | 0.1530 | ||
| 150 | 14.2 | 2.5 | 0.1 | 2.5 | 53.3 | 2.90 | 5.60 | 0.2060 | 0.1240 | ||
| 185 | 15.9 | 2.5 | 0.1 | 2.6 | 57.2 | 3.40 | 6.77 | 0.1640 | 0.0991 | ||
| 240 | 18.3 | 2.6 | 0.1 | 2.8 | 63.2 | 4.12 | 8.55 | 0.1250 | 0.0754 | ||
| 300 | 20.4 | 2.8 | 0.1 | 3.0 | 69.0 | 4.89 | 10.46 | 0.1000 | 0.0601 | ||
| 400 | 23.2 | 3.0 | 0.1 | 3.4 | 76.7 | 6.10 | 13.18 | 0.0778 | 0.0470 | ||
| 500 | 26.4 | 3.2 | 0.1 | 3.6 | 85.7 | 8.10 | 16.55 | 0.0605 | 0.0366 | ||
7)6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | |||
| Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||||
| mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km | |
| 25 | 6.0 | 3.4 | 0.1 | 2.1 | 38.7 | 1.30 | 1.75 | 1.2000 | 0.7270 | |
| 35 | 6.9 | 3.4 | 0.1 | 2.2 | 40.9 | 1.47 | 2.22 | 0.8680 | 0.5240 | |
| 50 | 8.2 | 3.4 | 0.1 | 2.3 | 43.9 | 1.70 | 2.50 | 0.6410 | 0.3870 | |
| 70 | 9.7 | 3.4 | 0.1 | 2.4 | 47.3 | 2.02 | 3.25 | 0.4430 | 0.2680 | |
| 95 | 11.3 | 3.4 | 0.1 | 2.5 | 51.0 | 2.42 | 4.12 | 0.3200 | 0.1930 | |
| 120 | 12.8 | 3.4 | 0.1 | 2.6 | 54.4 | 2.79 | 4.95 | 0.2530 | 0.1530 | |
| 150 | 14.2 | 3.4 | 0.1 | 2.7 | 57.6 | 3.17 | 5.87 | 0.2060 | 0.1240 | |
| 185 | 15.9 | 3.4 | 0.1 | 2.8 | 61.5 | 3.69 | 7.06 | 0.1640 | 0.0991 | |
| 240 | 18.3 | 3.4 | 0.1 | 2.9 | 66.9 | 4.38 | 8.82 | 0.1250 | 0.0754 | |
| 300 | 20.4 | 3.4 | 0.1 | 3.1 | 71.8 | 5.11 | 10.68 | 0.1000 | 0.0601 | |
| 400 | 23.2 | 3.4 | 0.1 | 3.3 | 78.3 | 6.24 | 13.32 | 0.0778 | 0.0470 | |
| 500 | 26.4 | 3.4 | 0.1 | 3.5 | 86.4 | 7.63 | 16.50 | 0.0605 | 0.0366 | |
8)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | ||||
| Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||||||
| mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km | ||
| 25 | 6.0 | 4.5 | 0.1 | 2.3 | 43.9 | 1.57 | 2.02 | 0.9270 | 0.7270 | ||
| 35 | 6.9 | 4.5 | 0.1 | 2.4 | 46.0 | 1.75 | 2.38 | 0.6680 | 0.5240 | ||
| 50 | 8.2 | 4.5 | 0.1 | 2.4 | 48.8 | 2.00 | 2.85 | 0.4936 | 0.3870 | ||
| 70 | 9.7 | 4.5 | 0.1 | 2.5 | 52.3 | 2.34 | 3.57 | 0.3420 | 0.2680 | ||
| 95 | 11.3 | 4.5 | 0.1 | 2.6 | 55.9 | 2.75 | 4.45 | 0.2464 | 0.1930 | ||
| 120 | 12.8 | 4.5 | 0.1 | 2.7 | 59.4 | 3.16 | 5.32 | 0.1955 | 0.1530 | ||
| 150 | 14.2 | 4.5 | 0.1 | 2.8 | 62.6 | 3.57 | 6.27 | 0.1587 | 0.1240 | ||
| 185 | 15.9 | 4.5 | 0.1 | 2.9 | 66.4 | 4.07 | 7.45 | 0.1271 | 0.0991 | ||
| 240 | 18.3 | 4.5 | 0.1 | 3.1 | 72.0 | 4.82 | 9.25 | 0.0976 | 0.0754 | ||
| 300 | 20.4 | 4.5 | 0.1 | 3.3 | 77.0 | 5.71 | 11.28 | 0.0778 | 0.0601 | ||
| 400 | 23.2 | 4.5 | 0.1 | 3.4 | 83.2 | 6.78 | 13.86 | 0.0615 | 0.0470 | ||
| 500 | 26.4 | 4.5 | 0.1 | 3.5 | 91.1 | 8.20 | 17.32 | 0.0487 | 0.0366 | ||
9)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | ||||
| Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||||||
| mm2 | mm | mm | mm2 | mm | mm | kg/m | kg/m | Ω/km | Ω/km | ||
| 25 | – | ||||||||||
| 35 | 6.9 | 5.5 | 0.1 | 2.4 | 50.3 | 2.00 | 2.63 | 0.8680 | 0.6680 | ||
| 50 | 8.2 | 5.5 | 0.1 | 2.5 | 53.3 | 2.26 | 3.11 | 0.6410 | 0.4936 | ||
| 70 | 9.7 | 5.5 | 0.1 | 2.6 | 56.8 | 2.62 | 3.85 | 0.4430 | 0.3420 | ||
| 95 | 11.3 | 5.5 | 0.1 | 2.8 | 60.6 | 3.07 | 4.77 | 0.3200 | 0.2464 | ||
| 120 | 12.8 | 5.5 | 0.1 | 2.9 | 64.1 | 3.49 | 5.65 | 0.2530 | 0.1955 | ||
| 150 | 14.2 | 5.5 | 0.1 | 3.0 | 67.3 | 3.91 | 6.61 | 0.2060 | 0.1587 | ||
| 185 | 15.9 | 5.5 | 0.1 | 3.1 | 71.2 | 4.44 | 7.81 | 0.1640 | 0.1271 | ||
| 240 | 18.3 | 5.5 | 0.1 | 3.3 | 76.8 | 5.21 | 9.64 | 0.1250 | 0.0976 | ||
| 300 | 20.4 | 5.5 | 0.1 | 3.3 | 81.3 | 6.10 | 11.66 | 0.1000 | 0.0778 | ||
| 400 | 23.2 | 5.5 | 0.1 | 3.5 | 87.7 | 7.20 | 14.28 | 0.0778 | 0.0615 | ||
| 500 | 26.4 | 5.5 | 0.1 | 3.8 | 96.0 | 9.15 | 17.80 | 0.0605 | 0.0487 | ||
10)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of Copper Tape |
Normal Thickness of Outer Sheath | Approx. Overall Dia. |
Approx. Net Weight | Max. D.C. Resistance of Conductor at 20ºC | ||
| Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||||
| mm2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
| 25 | |||||||||
| 35 | |||||||||
| 50 | 8.2 | 8.0 | 0.1 | 2.9 | 64.9 | 3.02 | 3.87 | 0.6410 | 0.4936 |
| 70 | 9.7 | 8.0 | 0.1 | 3.0 | 68.4 | 3.42 | 4.65 | 0.4430 | 0.3420 |
| 95 | 11.3 | 8.0 | 0.1 | 3.1 | 72.0 | 3.89 | 5.59 | 0.3200 | 0.2464 |
| 120 | 12.8 | 8.0 | 0.1 | 3.3 | 75.7 | 4.39 | 6.54 | 0.2530 | 0.1955 |
| 150 | 14.2 | 8.0 | 0.1 | 3.3 | 78.7 | 4.85 | 7.55 | 0.2060 | 0.1587 |
| 185 | 15.9 | 8.0 | 0.1 | 3.4 | 82.6 | 5.42 | 8.79 | 0.1640 | 0.1271 |
| 240 | 18.3 | 8.0 | 0.1 | 3.5 | 88.0 | 6.22 | 10.66 | 0.1250 | 0.0976 |
| 300 | 20.4 | 8.0 | 0.1 | 3.7 | 92.9 | 7.20 | 12.77 | 0.1000 | 0.0778 |
| 400 | 23.2 | 8.0 | 0.1 | 3.9 | 99.3 | 8.38 | 15.46 | 0.0778 | 0.0615 |
| 500 | 26.4 | 8.0 | 0.1 | 4.2 | 107.6 | 10.15 | 18.85 | 0.0605 | 0.0487 |
Wer wir sind China Heißer Verkäufer-mittleres Spannungs-XLPE Unarmoured Leistung-Isolierkabel Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.
Get Latest Price Request a quote
Popular Heißer Verkäufer-mittleres Spannungs-XLPE Unarmoured Leistung-Isolierkabel Produkte
Popular jpcable99 Produkte
Vde genehmigte H07rn-F Gummi umhülltes elektrisches kabel, Drähte, Energien-Kabel
Bewehrtes Netzkabel aus Stahlband (STA-Kabel)
BS-Standardstahl verstärkter Aluminiumleiter
600/1000V Multi Cores PVC Unarmoured Power Cable
Heißer Leiter-blank Leiter des Verkaufs-AAC
1kv, 11kv, 35kv, XLPE Isolierungs-Stahldraht-gepanzerte Kabel
Popular Millivolt-XLPE Unarmoured Leistung-Isolierkabel Produkte
Popular xlpe isolierkabel Produkte
Kabel ABC, Kabel ABC, Kabel Mit Niedriger Spannung, 0,6/1 kv Isoliert
Beutel 25kv sperrte Luftkabel 1core 240mm2 185mm2
Kupfer-0.6/1kv/Aluminiumenergien-Kabel 3X10+6mm2, 3X16+10mm2, 3X25+16mm2, 3X35+16mm2
Fester Kern oder fest gepresster verdrehter Sektor-Leiter
Servive Drop Cable XLPE Isolated Aerial Bundle Cable
Xhw-2-Aluminiumkabel, XLPE-Isolierkabel