Im Lieferumfang Enthaltenes Aluminiumkabel/Quadruplex Drop Service

China 
                                 Im Lieferumfang Enthaltenes Aluminiumkabel/Quadruplex Drop Service                              Herstellung und Lieferant

Im Lieferumfang Enthaltenes Aluminiumkabel/Quadruplex Drop Service image

Get Latest Price Request a quote

Basis Info

Modell Nr..
Quadruplex Drop Service

Zusätzliche Informationen.

Warenzeichen
Yifang Cable

Verpackung
Wooden Drum or Wooden-Steel Drum

Standard
CE SABS RoHS SGS UL CCC

Herkunft
Zhengzhou, China

HS-Code
8544492100

Produktionskapazität
5, 000, 000km/Month

Produktbeschreibung

Specifications
Standard: National Standard IEC and ASTM
Rated Voltage: 0.6/1KV, 11KV, 33KV
Construction: Phase conductor: Aluminum stranded(AAC)
Neutral conductor: Aluminum stranded(AAC), aluminum alloy stranded(AAAC), aluminum conductor steel reinforced(ACSR)
Insulation: XLPE or PE
Application: The cables are designed for aerial power lines and room-entrance wires with voltage up to and including 0.6/1KV.
Uesd for overhead service application such as street linghting, outdoor lighting and temporary service for cunstruction. Which improves the safety and reliance of electrified wire netting.

1 Type: Duplex Service Drop, Triplex Service Drop, Quadruplex Service Drop

A Duplex Service Drop
Applications: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.

B Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.

C Quadruplex Service Drop
Applications: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

2 Construction
A Phase Conductor construction: The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.

B Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:
Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded
Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded
Aluminum alloy 6201-T81, concentric-lay-stranded

C Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)
Alternatively, black linear low-density polyethylene (LDPE) insulation with a 75° C temperature rating is available upon request.

PEC mm2 conductor structure Approx.
Phase Neutral(Bare ACSR) insulation insulation Overall Approx. packing
(Compacted AL) Aluminium Steel material Thickness Diameter Weight Meters Per
(No./mm) (No./mm) (No./mm) (mm) (mm) (kg/km) Drum
1×16+1×16 7/1.72 6/1.72 1/1.72 XLPE 1.2 12.5 121.9 250-4000m
1×25+1×25 7/2.15 6/2.15 1/2.15 1.2 14.9 182.2 250-4000m
1×35+1×35 7/2.54 6/2.54 1/2.54 1.4 17.5 254.7 250-3500m
1×50+1×50 7/2.92 6/2.92 1/2.92 1.4 20.1 333.9 250-3000m
1×70+1×70 19/2.15 12/2.15 17/2.15 1.4 23.6 382.2 250-3000m
1×95+1×95 19/2.54 12/5.24 17/5.24 1.6 27.6 528.2 250-3000m
2×16+1×16 7/1.72 6/1.72 1/1.72 (HDPE) 1.2 14.2 187.6 250-4000m
2×25+1×25 7/2.15 6/2.15 1/2.15 1.2 16.7 273.8 250-3500m
2×35+1×35 7/2.54 6/2.54 1/2.54 1.4 19.7 386.9 250-3500m
2×50+1×50 7/2.92 6/2.92 1/2.92 1.4 22.5 506 250-3000m
2×70+1×70 19/2.15 12/2.15 7/2.15 1.4 26.1 617.2 250-3000m
2×95+1×95 19/2.54 12/5.24 7/5.24 1.6 30.5 850.9 250-3000m
3×16+1×16 7/1.72 6/1.72 1/1.72 1.2 16.3 253.3 250-3500m
3×25+1×25 7/2.15 6/2.15 1/2.15 1.2 19.1 371.9 250-3500m
3×35+1×35 7/2.54 6/2.54 1/2.54 1.4 22.5 519.1 250-3000m
3×50+1×50 7/2.92 6/2.92 1/2.92 1.4 25.7 678.1 250-3000m
3×70+1×70 19/2.15 12/2.15 7/2.15 1.4 29.7 1024.3 250-3000m
2×95+1×95 19/2.54 12/2.54 7/2.54 1.6 34.6

Specifications
1.Conductor: aluminum or copper
2. Insulation: XLPEor PVC
3.Stranded or solid conductor
4. IECstandard
5. abc cables

low voltage overhead bundled cable ABC

Specifications
ABC aerial bundle cable withAluminium stranded conductor(compacted or non- compacted), AAAC or ACSR messenger core.
Aluminium stranded conductor(compacted or non- compacted), AAAC messenger core(or ACSR messenger core), XLPE(or HDPE) insulated, Twisted (or Parallel)power cable
The product is a new type of aerial cable for power transmitting, It is extensively used in overhead power transmission line, It improves the safety and reliance of electrified wire netting.

SPEC mm2 conductor structure Approx.
Phase Neutral(Bare ACSR) insulation insulation Overall Approx. packing
(Compacted AL) Aluminium Steel material Thickness Diameter Weight Meters Per
(No./mm) (No./mm) (No./mm) (mm) (mm) (kg/km) Drum
1×16+1×16 7/1.72 6/1.72 1/1.72 XLPE 1.2 12.5 121.9 250-4000m
1×25+1×25 7/2.15 6/2.15 1/2.15 1.2 14.9 182.2 250-4000m
1×35+1×35 7/2.54 6/2.54 1/2.54 1.4 17.5 254.7 250-3500m
1×50+1×50 7/2.92 6/2.92 1/2.92 1.4 20.1 333.9 250-3000m
1×70+1×70 19/2.15 12/2.15 17/2.15 1.4 23.6 382.2 250-3000m
1×95+1×95 19/2.54 12/5.24 17/5.24 1.6 27.6 528.2 250-3000m
2×16+1×16 7/1.72 6/1.72 1/1.72 (HDPE) 1.2 14.2 187.6 250-4000m
2×25+1×25 7/2.15 6/2.15 1/2.15 1.2 16.7 273.8 250-3500m
2×35+1×35 7/2.54 6/2.54 1/2.54 1.4 19.7 386.9 250-3500m
2×50+1×50 7/2.92 6/2.92 1/2.92 1.4 22.5 506 250-3000m
2×70+1×70 19/2.15 12/2.15 7/2.15 1.4 26.1 617.2 250-3000m
2×95+1×95 19/2.54 12/5.24 7/5.24 1.6 30.5 850.9 250-3000m
3×16+1×16 7/1.72 6/1.72 1/1.72 1.2 16.3 253.3 250-3500m
3×25+1×25 7/2.15 6/2.15 1/2.15 1.2 19.1 371.9 250-3500m
3×35+1×35 7/2.54 6/2.54 1/2.54 1.4 22.5 519.1 250-3000m
3×50+1×50 7/2.92 6/2.92 1/2.92 1.4 25.7 678.1 250-3000m
3×70+1×70 19/2.15 12/2.15 7/2.15 1.4 29.7 1024.3 250-3000m
2×95+1×95 19/2.54 12/2.54 7/2.54 1.6 34.6 1413.7 250-3000m

Wer wir sind China Im Lieferumfang Enthaltenes Aluminiumkabel/Quadruplex Drop Service Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.

Get Latest Price Request a quote

Popular Abc Cable Produkte

ABC Cable

Hot Saleaerial Bundled Cable, ABC Cable, Overhead Cable, ASTM, BS, NFC, IEC, DIN Standard

Quadruplex Service Drop Cable, ACSR Neutral, Twisted 600 V Quadruplex (ANSI/ICEA S-76-474)

Low Voltage Aerial Bundled Cable

Duplex-Service-Drop AAC-Aluminiumleiter, "Collie", ASTM

Triplex Service Drop ACSR Neutralleiter Periwinkle

Popular Aerial Bundle Cable Produkte

High Quality ABC Aerial Bundled Cable with IEC60502 Standard

Popular Im Lieferumfang Enthaltenes Aluminiumkabel/Quadruplex Drop Service Produkte

  • No related articles
  • Popular yifangcable Produkte

    Hochfester 1X3 1X7 1X19 heißer eingetauchter Stahlkern-Kerl-Stütze-angeschwemmter Draht

    Niederspannungs-Stahlband Sta gepanzertes Untertagekabel-Aluminium-Kabel

    8kv Epr-Kabel Mit Isoliertem Gummi

    0,6/1kV 3 4 5 Kern PVC isoliert PVC ummantelt flexible nicht gepanzerte Netzkabel nicht gepanzerte Kabel, einzelne 150mmsq Kupferkabel

    22 kv N2xs (SE) Y 3 x 150 mm2 Kabel

    48/66kv Hochspannungs-XLPE-Netzkabel, 1 x 630 mm2 Kupferdraht Kabel Für Unterirdische Hochspannungsleitungen

    Tags: , , ,

    SCHNELLER UND ZUVERLÄSSIGER SERVICE FÜR IHR PROJEKT

    Wenden Sie sich noch heute an unsere geschulten Experten, um Ihre perfekte Stromversorgungslösung zu finden.

    STELLE EINE FRAGE