Basis Info

Modell Nr..
ACSR conductor

Art
Blank

Leitertyp
Stranded

Anwendung
Oben

Leitermaterial
Aluminium

Isoliermaterial
Blank

Material Form
Runddraht

Bescheinigung
ISO9001 ,
CE ,
CCC ,
RoHS ,
VDE

Zusätzliche Informationen.

Warenzeichen
Huatong

Verpackung
Wooden /Steel Wooden /Steel Package

Standard
10-800mm

Herkunft
in China

HS-Code
76149000

Produktionskapazität
5000tons/Month

Produktbeschreibung

Aluminum Conductor Line Overhead Conductor ACSR Acar AAC AAAC
aluminium bare conductors

Standards IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110
Certificate ISO 9001 and ISO 14001. CE ,SONCAP
Type AAC, AAAC, ACSR, AACSR&ACAR conductor

 
 
AAC, AAAC, ACSR, AACSR&ACAR conductor widely used in power transmission lines with various voltage levels.
Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.
1. Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM
(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.
Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.
Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
Packing:
Standard export wooden drums
 echnical details
 AAC Technical Characteristics Based on Standard DIN 48201 / DIN EN50182
  

Code number Area Number of wires Wire     diameter Conductor diameter Linear mass Rated strength D.C. resistance at 20oC
mm2 No. mm mm kg/km kN Ω/km
16 15.9 7 1.7 5.1 43.4 3.02 1.7986
25 24.2 7 2.1 6.3 66.3 4.36 1.1787
35 34.4 7 2.5 7.5 93.9 6.01 0.8317
50 49.5 7 3 9 135.2 8.41 0.5776
50 48.3 19 1.8 9 132.9 8.94 0.5944
70 65.8 19 2.1 10.5 180.9 11.85 0.4367
95 93.3 19 2.5 12.5 256.3 16.32 0.3081
120 117 19 2.8 14 321.5 19.89 0.2456
150 147.1 37 2.25 15.8 405.7 26.48 0.196
185 181.6 37 2.5 17.5 500.9 31.78 0.1588
240 242.5 61 2.25 20.3 671.1 43.66 0.1193
300 299.4 61 2.5 22.5 828.5 52.4 0.0966

 ACSR Technical Characteristics Based on Standard ASTM B232

Code
word
Size
(AWG or
kcmil)
Strand-
ing
(Al/Stl)
Diameter(ins.) Weight per 1000 ft. (Lbs) Content (%) Rated
strength
(Lbs)
Resistance
  Ω/1000 ft.
Allowable
ampacity+
(Amps)
Individual wire Steel
core
Complete
cable
Al St Total Al St DC at
20ºC
AC at
75ºC
Al Stl
Turkey 6 6/1 .0661 .0661 .0661 .198 24 12 36 67.88 32.12 1190 .641 .806 105
Swan 4 6/1 .0834 .0834 .0834 .25 39 18 57 67.87 32.12 1860 .403 .515 140
Swanate 4 7/1 .0772 .103 .103 .257 39 28 67 58.1 41.9 2360 .399 .519 140
Sparrow 2 6/1 .1052 .1052 .1052 .316 62 29 91 67.9 32.1 2850 .254 .332 184
Sparate 2 7/1 .0974 .1298 .1298 .325 62 45 107 58.12 41.88 3460 .251 .338 184
Robin 1 6/1 .1181 .1181 .1181 .354 78 37 115 67.88 32.12 3550 .201 .268 212
Raven 1/0 6/1 .1327 .1327 .1327 .398 99 47 145 67.89 32.11 4380 .159 .217 242
Quail 2/0 6/1 .1489 .1489 .1489 .447 124 59 183 67.88 32.12 5310 .126 .176 276
Pigeon 3/0 6/1 .1672 .1672 .1672 .502 156 74 230 67.87 32.13 6620 .100 .144 315
Penguin 4/0 6/1 .1878 .1878 .1878 .563 197 93 291 67.89 32.12 8350 .0795 .119 357
Waxwing 266.8 18/1 .1217 .1217 .1217 .609 250 39 289 86.43 13.57 6880 .0643 .0787 449
Partridge 266.8 26/7 .1013 .0788 .2363 .642 251 115 367 68.51 31.49 11300 .0637 .0779 475
Ostrich 300 26/7 .1074 .0835 .2506 .68 283 130 412 68.51 31.49 12700 .0567 .0693 492
Merlin 336.4 18/1 .1367 .1367 .1367 .684 315 49 365 86.43 13.57 8680 .0510 .0625 519
Linnet 336.4 26/7 .1137 .0885 .2654 .72 317 146 462 68.51 31.49 14100 .0505 .0618 529
Oriole 336.4 30/7 .1059 .1059 .3177 .741 318 209 526 60.35 39.65 17300 .0502 .0613 535
Chickadee 397.5 18/1 .1486 .1486 .1486 .743 373 58 431 86.43 13.57 9940 .0432 .0529 576
Brant 397.5 24/7 .1287 .0858 .2574 .772 374 137 511 73.21 26.79 14600 .0430 .0526 584
Lbis 397.5 26/7 .1236 .0962 .2885 .783 374 172 546 68.51 31.49 16300 .0428 .0523 587
Lark 397.5 30/7 .1151 .1151 .3453 .806 375 247 622 60.35 39.65 20300 .0425 .0519 594
Pelican 477 18/1 .1628 .1628 .1628 .814 447 70 517 86.44 13.56 11800 .0360 .0442 646
Flicker 477 24/7 .141 .094 .2819 .846 449 164 614 73.21 26.79 17200 .0358 .0439 655
Hawk 477 26/7 .1354 .1053 .316 .858 449 207 656 68.51 31.49 19500 .0356 .0436 659
Hen 477 30/7 .1261 .1261 .3783 .883 450 296 746 60.35 39.65 23800 .0354 .0433 666
Osprey 556.5 18/1 .1758 .1758 .1758 .879 522 82 603 86.43 13.57 13700 .0308 .0379 711
Parakeet 556.5 24/7 .1523 .1015 .3045 .914 524 192 716 73.21 26.79 19800 .0307 .0376 721
Dove 556.5 26/7 .1463 .1138 .3413 .927 524 241 765 68.51 31.49 22600 .0306 .0375 726
Eagle 556.5 30/7 .1362 .1362 .4086 .953 525 345 871 60.35 39.65 27800 .0303 .0372 734
Peacock 605 24/7 .1588 .1059 .3177 .953 570 209 779 73.2 26.8 21600 .0282 .0346 760
Squab 605 26/7 .1525 .1186 .3559 .966 570 262 832 68.51 31.49 24300 .0281 .0345 765
Wood duck 605.0 30/7 .142 .142 .426 .994 571 375 946 60.35 39.65 28900 .0279 .0342 774
Teal 605.0 30/19 .142 .0852 .426 .994 571 367 939 60.86 39.14 30000 .0279 .0342 773
Kingbird 636 18/1 .188 .188 .188 .94 596 94 690 86.43 13.57 15700 .0270 .0332 773
Swift 636.0 36/1 .1329 .1329 .1329 .93 596 47 643 92.72 7.28 13690 .0271 .0334 769
Rook 636 24/7 .1628 .1085 .3256 .977 599 219 818 73.22 26.78 22600 .0268 .0330 784
Grosbeak 636 26/7 .1564 .1216 .3649 .991 599 275 874 68.51 31.49 25200 .0267 .0328 789
Scoter 636.0 30/7 .1456 .1456 .4368 1.019 600 395 995 60.35 39.65 30400 .0256 .0325 798
Egret 636 30/19 .1456 .0874 .4368 1.019 600 386 987 60.85 39.15 31500 .0266 .0326 798
Flamingo 666.6 24/7 .1667 .1111 .3333 1 628 230 858 73.21 26.79 23700 .0256 .0315 807
Gannet 666.6 26/7 .1601 .1245 .3736 1.014 628 289 916 68.51 31.49 26400 .0255 .0313 812
Stilt 715.5 24/7 .1727 .1151 .3453 1.036 674 247 920 73.21 26.79 25500 .0239 .0294 844
Starling 715.5 26/7 .1659 .129 .3871 1.051 674 310 984 68.51 31.49 28400 .0238 .0292 849
Redwing 715.5 30/19 .1544 .0927 .4633 1.081 676 435 1110 60.85 39.15 34600 .0236 .0290 859
Coot 795 36/1 .1486 .1486 .1486 1.04 745 58 804 92.72 7.28 16710 .0217 .0268 884
Drake 795 26/7 .1749 .136 .408 1.107 749 344 1093 68.51 31.49 31500 .0214 .0263 907
Tern 795 45/7 .1329 .0886 .2658 1.063 749 146 895 83.67 16.33 22100 .0216 .0269 887
Condor 795 54/7 .1213 .1213 .364 1.092 749 274 1023 73.21 26.79 28200 .0215 .0272 889
Mallard 795 30/19 .1628 .0977 .4884 1.14 751 483 1234 60.86 39.14 38400 .0213 .0261 918
Ruddy 900 45/7 .1414 .0943 .2828 1.131 848 165 1013 83.67 16.33 24400 .0191 .0239 958
Canary 900 54/7 .1291 .1291 .3873 1.162 848 310 1158 73.22 26.78 31900 .0190 .0241 961
Rail 954 45/7 .1456 .0971 .2912 1.165 899 175 1074 83.67 16.33 25900 .0180 .0225 993
Cardinal 954 54/7 .1329 .1329 .3987 1.196 899 329 1227 73.21 26.79 33800 .0179 .0228 996
Ortolan 1033.5 45/7 .1515 .101 .3031 1.212 973 190 1163 83.67 16.33 27700 .0167 .0209 1043
Curlew 1033.5 54/7 .1383 .1383 .415 1.245 973 356 1330 73.21 26.79 36600 .0165 .0211 1047
Bluejay 1113 45/7 .1573 .1048 .3145 1.258 1048 205 1253 83.67 16.33 29800 .0155 .0194 1092
Finch 1113 54/19 .1436 .0861 .4307 1.292 1053 375 1429 73.72 26.28 39100 .0154 .0197 1093
Bunting 1192.5 45/7 .1628 .1085 .3256 1.302 1123 219 1343 83.67 16.33 32000 .0144 .0182 1139
Grackle 1192.5 54/19 .1486 .0892 .4458 1.337 1129 402 1531 73.72 26.28 41900 .0144 .0184 1140
Bittern 1272 45/7 .1681 .1121 .3362 1.345 1198 234 1432 83.67 16.33 34100 .0135 .0171 1184
Pheasant 1272 54/19 .1535 .0921 .4605 1.381 1204 429 1633 73.71 26.29 43600 .0135 .0173 1187
Dipper 1351.5 45/7 .1733 .1155 .3466 1.386 1273 248 1521 83.67 16.33 36200 .0127 .0162 1229
Martin 1351.5 54/19 .1582 .0949 .4746 1.424 1279 456 1735 73.72 26.28 46300 .0127 .0163 1232
Bobolink 1431 45/7 .1783 .1189 .3566 1.427 1348 263 1611 83.67 16.33 38300 .0120 .0153 1272
Lapwing 1590 45/7 .188 .1253 .3759 1.504 1498 292 1790 83.67 16.33 42200 .0108 .0139 1354
Falcon 1590 54/19 .1716 .103 .5148 1.544 1505 536 2041 73.72 26.28 54500 .0108 .0140 1359
Chukar 1780 84/19 .1456 .0874 .4368 1.602 1685 386 2072 81.35 18.65 51000 .0097 .0125 1453
Bluebird 2156 84/19 .1602 .0962 .4808 1.762 2040 468 2508 81.34 18.66 60300 .00801 .0105 1623
Kiwi 2167 72/7 .1735 .1157 .347 1.735 2051 249 2300 89.17 10.82 49800 .00801 .0106 1607
+Conductor temperature of 75ºC, ambient temperature 25ºC, emissivity 0.5, wind 2 ft./sec., in sun.

ACSR Technical Characteristics Based on Standard BS 215-2   
 

Code name Nominal aluminium area Stranding and wire     diameter Sectional area of aluminium Total sectional area Approx. overall diameter Approx. mass Calculated D.C. resistance at 20oC Calculated breaking load
Al Steel
mm2 No./mm mm2 mm2 mm kg/km Ω/km kN
RABBIT 50 6/3.35 1/3.35 52.88 61.7 10.05 214 0.5426 18.35
DOG 100 6/4.72 7/1.57 105 118.5 14.15 394 0.2733 32.7
WOLF 150 30/2.59 7/2.59 158.1 194.9 18.13 726 0.1828 69.2
DINGO 150 18/3.35 1/3.35 158.7 167.5 16.75 506 0.1815 35.7
LYNX 175 30/2.79 7/2.79 183.4 226.2 19.53 842 0.1576 79.8
ZEBRA 400 54/3.18 7/3.18 428.9 484.5 28.62 1621 0.0674 131.9

 
 
 AAAC Technical Characteristics Based on Standard BS 3242  
 

Code name Nominal aluminium area Stranding and wire     diameter Sectional area Approx. overall diameter Approx. mass Calculated D.C. resistance at 20oC Calculated breaking load
mm2 No./mm mm2 mm kg/km Ω/km kN
ALMOND 25 7/2.34 30.1 7.02 82 1.094 8.44
CEDAR 30 7/2.54 35.47 7.62 97 0.9281 9.94
FIR 40 7/2.95 47.84 8.85 131 0.688 13.4
HAZEL 50 7/3.30 59.87 9.9 164 0.5498 16.8
OAK 100 7/4.65 118.9 13.95 325 0.2769 33.3
ASH 150 19/3.48 180.7 17.4 497 0.183 50.65
ELM 175 19/3.76 211 18.8 580 0.1568 59.1
UPAS 300 37/3.53 362.1 24.71 997 0.09155 101.5

 

Wer wir sind China Überkopfleiter ASTM-Standards ACSR/AAC/Acar/AAAC-Kabel/Condcuctor Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.

Get Latest Price Request a quote

Popular aac leiter Produkte

AAAC AAC ACSR-Leiter (Aluminium-Leiter, stahlverstärkt)

Oberleitung Aus Blanker Aluminiumlitze

Anbieter und Hersteller von AAC-Elektrokabeln

Fabrikpreis AAC AAAC ACSR Aluminiumlegierung Leiter ASTM IEC Standard

Alle Aluminiumleiter Orchid/636mcm Heuchera650mcm Kennzeichnung 700 mcm AAC Leiter

AAC-Oberleitungskabel aus blankem Aluminiumleiter

Popular acsr leiter Produkte

Leiter des ACSR Hund100

Obenliegender blank Leiter AAC Rose/Aster/Oxlip

Obenliegende Leiter, AAC/AAAC/ACSR

Jyxl2015jl01/Jl/G1a ACSR Aluminium angeschwemmtes Leiter Aluminium-Stahl Leiter-Kabel

General Cable ACSR Steel Core Dog Rabbit Drake ACSR Bare AAC AAAC ACSR-Kabel

AAC AAAC ACSR Aluminiumleiter-blank angeschwemmter Leiter

Popular huatongcable Produkte

AAAC-Leiter ASTM B399, Blanke Aluminiumlegierung 6201-T81, 500 mcm

6,35/11 kv Elektrokabel aus Kupfer mit einem Kern und U-Bahn

China Berühmter Hersteller Cu/Al Conductor XLPE-Isolierter Stahldraht Gepanzert

AAC-Leitung Für Freie Leitung

Oberleiter Aluminium Strand AAC Kabel Cosmos

8 AWG Kupferlitze

Popular Überkopfleiter ASTM-Standards ACSR/AAC/Acar/AAAC-Kabel/Condcuctor Produkte

  • No related articles
  • Tags: , , ,

    SCHNELLER UND ZUVERLÄSSIGER SERVICE FÜR IHR PROJEKT

    Wenden Sie sich noch heute an unsere geschulten Experten, um Ihre perfekte Stromversorgungslösung zu finden.

    STELLE EINE FRAGE