1. Application
0.6/1KV AAC/AAAC/ACSR XLPE/PE Insulation ABC cable AAAC conductor has been widely used in power transmission lines and electricity distribution lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost large transmission capacity. And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
2. Standard
We can produce as per the standard of GB, IEC, ASTM,DIN,CSA,JIS and also particularly customize and manufacture according to your special requirement.
Standards / Testing Specifications
IEC 61089, BS 3242, DIN 48201, ASTM B399, BS EN50183, GB/T 1179-2008
Working conditions aerial insulation power cable
1) Rated voltage: 0.6kV/1Kv
2) The tallest working temperature of the cable conductor; XLPE insulation cable: 90°C;
HDPE insulation cable: 75°C;
3) During having a short (lasting less than 5 seconds) the maximum temperature;
XLPE insulated cables is 250°C;
HDPE insulated cable is 150°C
4) During the cable lying, the ambient temperature must be above-20°C
5) Bending radius allowance of the cable;
A)1Kv aerial insulation power cable:
It should be no less than 4D for the cable with outer diameter less than 25mm;
It should be no less than 6D for the cable with outer diameter of 25mm or more;
B) 10kV aerial insulation power cable:
Single core cable: 20 (D+d)±5%mm;
Multi-core cable:15 (D+d)±%mm
Formula inside: D-Actual cable outer diameter;
d-Actual conductor outer diameterl
Standard Packaging
As provided by standards and customer’s requirement.
|
BS7884-1997 |
|||||
|
Nominal Area |
Stranding |
Diameter of conductor |
Linear mass |
Rated strength |
D.C. resistance at 20°C |
|
mm2 |
No./mm |
mm |
Kg/km |
KN |
Ω/km |
|
10 |
7/1.35 |
4.05 |
89.82 |
3.752 |
1.829 |
|
14 |
7/1.6 |
4.8 |
126.2 |
5.627 |
1.30300 |
|
16 |
3/2.65 |
5.72 |
148.30 |
6.194 |
1.10600 |
|
16 |
7/1.7 |
5.10 |
142.40 |
5.946 |
1.15400 |
|
25 |
7/2.1 |
6.30 |
217.30 |
9.073 |
0.75630 |
|
32 |
3/3.75 |
8.10 |
296.90 |
12.4 |
0.55200 |
|
32 |
7/2.46 |
7.38 |
298.20 |
12.442 |
0.54970 |
|
35 |
7/2.5 |
7.50 |
308.00 |
12.86 |
0.53370 |
|
50 |
7/3.00 |
9.00 |
443.50 |
18.52 |
0.37060 |
|
50 |
19/1.8 |
9.00 |
435.80 |
17.7 |
0.38190 |
|
70 |
7/3.55 |
10.65 |
621.10 |
25.93 |
0.26460 |
|
70 |
19/2.1 |
10.50 |
593.20 |
24.09 |
0.28060 |
|
95 |
19/2.5 |
12.50 |
840.70 |
34.14 |
0.19800 |
|
100.0 |
7/4.3 |
12.90 |
911.20 |
36.54 |
0.18100 |
|
120.0 |
19/2.8 |
14.00 |
1055.00 |
42.83 |
0.15780 |
|
125.0 |
19/2.9 |
14.50 |
1131.00 |
45.94 |
0.14710 |
|
150.0 |
19/3.2 |
16.00 |
1377.00 |
55.94 |
0.12080 |
|
150.0 |
37/2.25 |
15375.00 |
1334.00 |
53.88 |
0.12640 |
|
185.0 |
19/3.55 |
17.75 |
1695.00 |
68.86 |
0.09815 |
|
185.0 |
37/2.5 |
17.75 |
1647.00 |
66.49 |
0.10240 |
| Phase | Phase | Phase | Approx.Overall Diameter | Max. D.C. Resistance of Conductor at 20 Centigrade | |||
| AAC+UV-XLPE | Compact Conductor | UV-XLPE Insulation | |||||
| No.X Normal Cross Section of Cores | No.of Al Wires | Overall Diameter | Normal Thickness | Min. | Diameter | ||
| No. X mm 2 | – | mm | mm | mm | mm | mm | ohm/km |
| 1 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 6.05 | 3.08 |
| 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 7.20 | 1.91 |
| 1 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 8.40 | 1.20 |
| 1 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 9.80 | 0.868 |
| 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 11.10 | 0.641 |
| 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 12.60 | 0.443 |
| 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 14.80 | 0.320 |
| 1 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 16.20 | 0.253 |
| 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 18.20 | 0.206 |
| 1 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 20.20 | 0.164 |
| 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 22.80 | 0.125 |
| 2 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 12.10 | 3.08 |
| 2 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 14.40 | 1.91 |
| 2 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 16.80 | 1.20 |
| 2 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 19.60 | 0.868 |
| 2 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 22.20 | 0.641 |
| 2 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 25.20 | 0.443 |
| 2 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 29.60 | 0.320 |
| 2 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 32.40 | 0.253 |
| 2 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 36.40 | 0.206 |
| 2 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 40.40 | 0.164 |
| 2 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 45.60 | 0.125 |
| 3 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 13.07 | 3.08 |
| 3 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 15.55 | 1.91 |
| 3 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 18.14 | 1.20 |
| 3 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 21.17 | 0.868 |
| 3 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 23.98 | 0.641 |
| 3 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 27.22 | 0.443 |
| 3 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 31.97 | 0.320 |
| 3 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 34.99 | 0.253 |
| 3 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 39.31 | 0.206 |
| 3 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 43.63 | 0.164 |
| 3 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 49.25 | 0.125 |
| 4 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 14.64 | 3.08 |
| 4 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 17.42 | 1.91 |
| 4 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 20.33 | 1.20 |
| 4 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 23.72 | 0.868 |
| 4 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 26.86 | 0.641 |
| 4 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 30.49 | 0.443 |
| 4 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 35.82 | 0.320 |
| 4 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 39.20 | 0.253 |
| 4 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 44.04 | 0.206 |
| 4 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 48.88 | 0.164 |
| 4 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 55.18 | 0.125 |
Wer wir sind China ABC-Kabel mit Überkopflitze und AAC ACSR AAAAC-Neutralmeldung Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.
Get Latest Price Request a quote
Popular abc-kabel Produkte
Triplex ASTM Standard Portunus 4/0-19 Aluminium AAC Kern XLPE/PE isoliert Antennenkabel
ABC-Kabel 2X1/0AWG+1/0AWG entblössen AAAC Kurier Iceas76-474
Duplex-, Triplex, Quadruplex Service Absinken Bunded ABC-Kabel für Sekundärverteilungs-Kabel
ABC-Kabel 2*6+6AWG mit Cer RoHS UL-Standard
Antennenkabel Der Besten Qualität
ABC-Kabel, überhängender Luftleitungs-Kabelbündel mit XLPE/PVC-Isolierung
Popular ABC-Kabel mit Überkopflitze und AAC ACSR AAAAC-Neutralmeldung Produkte
Popular huatongcable Produkte
BBU-Gleichstromkabel, halogenfreie Isolierung
Feuerverzinkter Stahldraht Mit Heißem Abblendlicht, 7/16 Zoll
AAAAC-Anschlusskabel aus Aluminiumlegierung nach ASTM B399
450/750 V Gebäudedraht Elektrokabel Cooper Draht
XLPE-Isoliertes Netzkabel aus Stahldraht mit Armored PVC-Ummantelung
BS 183 Standard Verzinktes Stahldrahtseil Gsw
Popular zusammengerolltes luftkabel Produkte
Antenne Mit Abc-Kabel XLPE Isoliert - AS/NZS 3560.1
0.6/1kv XLPE Isolierung ABC-Kabel
Antenne Mit Abc-Kabel XLPE Isoliert 4 * 70mm2 - AS/NZS 3560.1
China-Lieferanten-Quadruplex Service-Absinken ABC-Kabel
Antennenbündel Kabel-ABC-Antennenkabel Mit ACSR Messenger Core
Passte alle Typen Luftservice-konzentrisches Kabel 600V an
Tags: abc-kabel, ABC-Kabel mit Überkopflitze und AAC ACSR AAAAC-Neutralmeldung, huatongcable, zusammengerolltes luftkabel