Power Cable Bare Conductor AAC - All Aluminum Stranded Conductor Overhead
Power Cable Bare Conductor AAC - All Aluminum Stranded Conductor Overhead image
Get Latest Price Request a quote
Grundlegende Informationen.
Produktbeschreibung
PRODUCT DESCRIPTION
Push Pull Cable Auto Aisg Ret Flexible Motorcycle Control Cable Operating characteristics
1.The maximum permissible continuous operating temperature is 70ºC
2.The lowest installation temperature of the cable is 0ºC.
3.Permissible Min. Bending radius: not less than 6 times of the completed cable diameter for unarmoured cable; not less than 12 times of the completed cable diameter for armoured or copper tape screened cable; not less than 6 times of the completed cable diameter for screened flexible cable.
SPECIFICATION
Normal type Flame retardant
WDZC-YJY/WDZB-YJY/WDZ YJY Cu conductor XLPE insulated PVC sheathed low smoke zero halogen flame resistant power cable
WDZC-YJY23
WDZB-YJY23
WDZAYJY23 Cu conductor XLPE insulated polyolefin sheathed internal steel type armored low smoke zero halogen flame resistant power cable
WDZC-KYJY
WDZB-KYJY
WDZA-KYJY Cu conductor XLPE inSUlated polyolefin Sheathed low Smoke Zero halogen flame resistant control cable
WDZC-KYJY23 WDZB-KYJY23 WDZA-KYJY23 Cu conductor XLPE insulated polyolefin sheathed internal steel type armored low smoke zero halogen flame resistant power cable
.Standards:
The cable is manufactured according to GB/T 19666. The rated voltage Uo/U of the cable is up to 0.6/kV.
.Operation characteristic
1. Rated voltage Uo/U: up to 0.6/1kV
2. Maximum rated temperature
2.1 PVC insulated cable: The maximum operating ternperature of cores shall not exceed 70°C when the cable is used for long period. The temperature of cores shall not exceed 160°C at short circuit (the max. duration dose not exceed 5 seconds).
2.2 XLPE insulated cable: The maximum operating temperature of cores shall not exceed 90°C when the cable is used for long period.The temperature of cores shall not exceed 250°C at short circuit (the max. duration dose not exceed 5 seconds).
.Installation requirement
Cable installation temperature shall not be less then 0°C.The permissible bending radius of cable shall not be less,then 10 times of the cable’s diameter. The cable is suitable for the places have special requirement to fire resistance,light transmittance. HCI and toxicity..
Specification
Power cable
Nominal cross-sectional area:1.5-630mm2.
Control cable
Nominal cross-sectional area:0.75-10mm2.
.Main Technical parameter
Flame resistant property
Test cable bunching combustion according to GB/T 19666 or IEC 60332-3 standards.
ZA: the nonmetal content of cable is 7L per meter, time of
supply fire is40 minute.
ZB: the nonmetal content of cable is 3.5L per meter, time
of supply fire is 40 minute.
ZC: the nonmetal content of cable is 1.5L per meter, time
of supply fire is 20 minute.
Test result: the maximal charring height should not exceed 2.5m.
Henan Kingyear Aluminum Industry Group was founded in 2006, located in Gongyi industry area of Henan Province. Our group consists of 3 main subsidiaries, business specialized in develop, manufacture and distribution of Aluminum products including Aluminum…
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(„,“).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
Wer wir sind China Power Cable Bare Conductor AAC - All Aluminum Stranded Conductor Overhead Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.
Get Latest Price Request a quote
Popular aac Produkte
450mcm ASTM Standard Aluminium Elektrisches AAC-Kabel
Verkauf aller Aac-Hersteller/Lieferanten Für Aluminiumleiter/Kabel
Alles Aluminiumleiter-Kabel-blank Leiter-Kabel
Meistverkaufte AAC-Allaluminium-blanker Litze
Aluminium-AAC Leiter-Energien-Kabel
Popular Aluminum Produkte
Niedrige und mittlere Spannung XLPE China Urd Aluminium Cable Power Mv90, MV105
Elektrische Kupferkabelleistung für Niederspannungs- und Mittelspannungsbauindustrie Mv90, MV105
Erdbau XLPE/EPR Isolierung Urd Kabel Mittelspannungsleistung Mv90, MV105
Max. 90 Grad oder 105degre CSA68,5 elektrische Leiter LLDPE Ummantelung
Rote Streifen Mittelspannungsversorgung Mv90, MV105 Aluminium 15kV Kabel
XLPE Underground XLPE/EPR Isolierung Urd Kabel Mittelspannungsleistung Mv90, MV105
Popular kingyear Produkte
CSA-gelistet Typ Teck 90 10/2 Teck90 Aia Kanadisches Kupfer Gebäudetraht 600V
Blank Coppr AWG10/12/16/18 AWG4 21mm2 versenkbares Pumpen-Energien-Kabel
Hippa Triplex Fabrik-Fertigung ABC-Kabel des ABC-Kabel-6AWG China
Acs angeschwemmter Draht-/plattierter Aluminiumstahl/Alumoweld Draht
Platte/Blatt der Fabrik-Großhandelsaluminiumlegierung-5754aluminium für Baumaterialien