Primary Ud Cable, 25 Kv, Al/Tr-XLPE/Neutral/LLDPE (AEIC CS 8/ICEA S-94-649)

China 
                                 Primary Ud Cable, 25 Kv, Al/Tr-XLPE/Neutral/LLDPE (AEIC CS 8/ICEA S-94-649)                              Herstellung und Lieferant

Primary Ud Cable, 25 Kv, Al/Tr-XLPE/Neutral/LLDPE (AEIC CS 8/ICEA S-94-649) image

Get Latest Price Request a quote

Basis Info

Modell Nr..
Primary UD Cable

Anwendung
U-Bahn

Spannung
Nieder-und Mittelspannung Kabel

Strom
DC-Kabel

Isoliermaterial
XLPE

Material Form
Runddraht

Bescheinigung
ISO ,
CCC

Zusätzliche Informationen.

Warenzeichen
DingAn or OEM

Verpackung
Heated Steel-Wooden Drum/Steel Drum

Standard
SGS

Herkunft
Jiangsu Yixing, China

HS-Code
8544601200

Produktionskapazität
12000 Km/Year

Produktbeschreibung

Primary UD Cable, 25 KV, AL/TR-XLPE/Neutral/LLDPE (AEIC CS 8/ICEA S-94-649)
Applications:
Predominantly used for primary underground distribution; Suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 15, 000 volts or less and at conductor temperatures not to exceed 90° C for normal operation.
Specifications:
Primary UD Cable meets or exceeds the following ASTM specifications:
B-3 Soft Annealed Copper Wire.
B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft.
B-230 Aluminum, 1350-H19 Wire for Electrical Purposes.
B-231 Aluminum 1350 Conductors, Concentric-Lay-Stranded.
B-609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes.
Primary UD Cable is manufactured to the latest edition of the following specifications, and in case of specification conflicts, in the order listed:
ANSI/ICEA S-94-649
AEIC CS-8
RUS U-1
Construction:
The phase conductor is concentrically stranded, compressed soft copper or 1350-H16/26 aluminum alloy. The cable is composed of the conductor with moisture block in the strands, covered by a semi-conducting cross-linked polyethylene strand shield, a tree-retardant cross-linked polyethylene primary insulation, and a semi-conducting cross-linked polyethylene insulation shield. Conductors are available with either 100% or 133% insulation levels. A concentric neutral of bare copper wires and an insulating polyethylene jacket is applied over the insulation shield. The cable is identified by surface print on the jacket and with the lightning bolt symbol for supply cables indented in the jacket. A semi-conducting polyethylene jacket is available upon request.
Maximum Conductor Normal Operation: – 90O C;
Emergency Overload: – 130O C
Temperatures: Short Circuit – 250 C
Application: Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1/3 Neutral Full Neutral
Size AWG or kcmil Number of Strands Nominal OD Over Insulation in Number of Wires Size AWG Jacket Thickness mil Approximate Outside Diameter in Approximate Net Weight lb/kft Size AWG or kcmil Number of Strands Nominal OD Over Insulation in Number of Wires Size AWG Jacket Thickness mil Approximate Outside Diameter in Approximate Net Weight lb/kft
Aluminum 100% Insulation Level (260 mil)
1 19 0.88 6 14 50 1.19 578 1 19 0.88 13 14 50 1.19 662
1/0 1 0.89 6 14 50 1.19 594 1/0 1 0.89 16 14 50 1.19 715
1/0 19 0.92 6 14 50 1.23 621 1/0 19 0.92 16 14 50 1.23 742
2/0 19 0.97 7 14 50 1.27 685 2/0 19 0.97 20 14 50 1.27 842
3/0 19 1.02 9 14 50 1.34 794 2/0 19 0.97 13 12 50 1.30 877
4/0 19 1.07 11 14 50 1.40 894 3/0 19 1.02 25 14 50 1.34 987
250 37 1.13 13 14 50 1.46 987 3/0 19 1.02 16 12 50 1.38 1021
350 37 1.23 18 14 50 1.56 1204 4/0 19 1.07 32 14 50 1.40 1147
500 37 1.36 25 14 80 1.75 1575 4/0 19 1.07 20 12 50 1.43 1175
500 37 1.36 16 12 80 1.78 1618 4/0 19 1.07 13 10 50 1.48 1227
750 61 1.57 24 12 80 2.02 2200 250 37 1.13 25 12 50 1.49 1341
750 61 1.57 15 10 80 2.06 2252 250 37 1.13 16 10 50 1.53 1390
1000 61 1.72 31 12 80 2.17 2674 350 37 1.23 32 12 50 1.59 1633
1000 61 1.72 20 10 80 2.21 2748 350 37 1.23 20 10 80 1.70 1740
1000 61 1.72 16 9 80 2.24 2789 350 37 1.23 16 9 80 1.72 1772
500 37 1.36 29 10 80 1.83 2244
750 61 1.57 28 8 80 2.12 3223
1000 61 1.72 37 8 80 2.27 4008
Aluminum 133% Insulation Level (320 mil)
1/0 1 1.01 6 14 50 1.31 691 1/0 1 1.01 16 14 50 1.31 811
1/0 19 1.05 6 14 50 1.37 744 1/0 19 1.05 16 14 50 1.37 865
2/0 19 1.09 7 14 50 1.42 812 2/0 19 1.09 20 14 50 1.42 969
3/0 19 1.14 9 14 50 1.47 903 2/0 19 1.09 13 12 50 1.45 1007
4/0 19 1.20 11 14 50 1.52 1007 3/0 19 1.14 25 14 50 1.47 1096
250 37 1.25 13 14 50 1.58 1105 3/0 19 1.14 16 12 50 1.50 1132
350 37 1.35 18 14 80 1.74 1398 4/0 19 1.20 32 14 50 1.52 1260
500 37 1.48 25 14 80 1.87 1715 4/0 19 1.20 20 12 50 1.55 1290
500 37 1.48 16 12 80 1.91 1760 4/0 19 1.20 13 10 50 1.60 1346
750 61 1.69 24 12 80 2.14 2361 250 37 1.25 25 12 50 1.61 1461
750 61 1.69 15 10 80 2.18 2417 250 37 1.25 16 10 80 1.72 1581
1000 61 1.84 31 12 80 2.29 2846 350 37 1.35 32 12 80 1.78 1831
1000 61 1.84 20 10 80 2.33 2924 350 37 1.35 20 10 80 1.82 1876
1000 61 1.84 16 9 80 2.36 2966 350 37 1.35 16 9 80 1.84 1910
500 37 1.48 29 10 80 1.95 2389
750 61 1.69 28 8 80 2.24 3391
1000 61 1.84 37 8 80 2.39 4188

Wer wir sind China Primary Ud Cable, 25 Kv, Al/Tr-XLPE/Neutral/LLDPE (AEIC CS 8/ICEA S-94-649) Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.

Get Latest Price Request a quote

Popular 25 kv Produkte

Mv-105, Power Cable, 25 KV, 3/C, Cu/Epr/Cts/CPE (ICEA S-93-639/NEMA WC71/UL 1072)

25 kv, 28 kv, MV-Konzentrisches Nullleiter aus Kupfer/Aluminium

HauptUd Cable, 25 KV, Cu/Epr/Neutral/LLDPE (AEIC CS 8/ICEA S-94-649)

Baum Wire Cable, Overhead Spacer Cable, 25 KV, 3-lagiges AAC (ANSI/ICEA S-66-524)

Kabelbäume, 25 Kv, 3-Schicht AAAC AAC ACSR ANSI/Icea S-66-524

Primary Ud Cable, 25 Kv, Al/Epr/Neutral/LLDPE (AEIC CS 8/ICEA S-94-649)

Popular Al/Tr-XLPE/Neutral/LLDPE (AEIC CS 8/ICEA S-94-649) Produkte

HauptUd Cable, 8 KV, Al/Tr-XLPE/Neutral/LLDPE (AEIC CS 8/ICEA S-94-649)

Primary Ud Cable, 15 Kv, Al/Tr-XLPE/Neutral/LLDPE (AEIC CS 8/ICEA S-94-649)

Primary Ud Cable, 35 Kv, Al/Tr-XLPE/Neutral/LLDPE (AEIC CS 8/ICEA S-94-649)

HauptUd Cable, 5 KV, Al/Tr-XLPE/Neutral/LLDPE (AEIC CS 8/ICEA S-94-649)

Popular boancable Produkte

500 CY, 300/500 V, flexibles Cu/PVC/Tcwb/PVC (Vde 0281-13) steuern

G-Gaschromatographie, Mining Cable, Cu/Epr/CPE, 3/C, 2kv (ICEA S-75-381/NEMA WC-58) schreiben

Gsw, Spanndraht, Aufenthalt-Draht, Zink-Überzogener Stahldraht (Iec 60888)

N2xsey, Power Cable, 12/20 KV, 3/C, Cu/XLPE/Cws/PVC (LÄRM-Vde 0276-620)

Cu/XLPE/Cts/PVC, Power Cable, 3.6/6 (7.2) KV, 1/C (Iec 60502-2)

Liycy (b) TP-Daten-Kabel, 300/500 V, flexibles Cu/PVC/Petp/Tcwb/PVC (LÄRM-Vde 0812)

Popular Power Cable Produkte

Cu/XLPE/Cts/PVC, Power Cable, 3.6/6 (7.2) KV, 3/C (Iec 60502-2)

Cu/XLPE/Cts/PVC/Awa/PVC, Power Cable, 6.35/11 KV, 1/C (BS 6622)

N2xsey, Power Cable, 6/10 KV, 3/C, Cu/XLPE/Cws/PVC (LÄRM-Vde 0276-620)

800mm2 300mm2 120mm2 4 Core Power Armoured Industrial Cable

Na2X2y, Power Cable, 0.6/1 KV, Al/XLPE/HDPE (Vde 0276-603/HD 603)

Al/XLPE/Cts/PVC/Awa/PVC, Power Cable, 12/20 (24) KV, 1/C (Iec 60502-2)

Tags: , , , , ,

SCHNELLER UND ZUVERLÄSSIGER SERVICE FÜR IHR PROJEKT

Wenden Sie sich noch heute an unsere geschulten Experten, um Ihre perfekte Stromversorgungslösung zu finden.

STELLE EINE FRAGE