Einzelner Aluminiumkern 1X16mm2 ABC Kabel PE/PVC-Isolierung

China 
                                 Einzelner Aluminiumkern 1X16mm2 ABC Kabel PE/PVC-Isolierung                              Herstellung und Lieferant

Einzelner Aluminiumkern 1X16mm2 ABC Kabel PE/PVC-Isolierung image

Get Latest Price Request a quote

Basis Info

Modell Nr..
ABC Cable

Art
Isolierte

Leitertyp
Solide

Anwendung
Oben ,
U-Bahn

Leitermaterial
Aluminium

Isoliermaterial
XLPE

Material Form
Runddraht

Bescheinigung
ISO9001 ,
CCC

Zusätzliche Informationen.

Warenzeichen
HUATONG

Verpackung
Drum

Standard
GB/T 12527

Herkunft
China

HS-Code
8544492100

Produktionskapazität
5000km/Month

Produktbeschreibung

APPLICATION
Medium voltage Aerial bundled cables are mainly used for secondary overhead lines on poles or as feeders
to residential premises.
STANDARDS
Basic design to IEC 60502 / AS/NZS 3599-1 standards
CABLE CONSTRUCTION
Phase Conductor: Circular compacted stranded H68 aluminium to BS2627.
Conductor Screen: Extruded semi-conductive layer.
insulation: XLPE.
insulation Screen: Extruded semi-conductive layer.
metallic Screen(optional): Copper wire screen or copper tape screen.
Separator: Semi-conductive swellable tape.
outer Sheath: HDPE.
Support Conductor: Galvanized steel wires.
Assembly: Three XLPE insulated screened cores are bundled around the galvanized steel
wires in a right hand lay.
Construction Parameters
IEC 60502 6.35/11 kV ABC for Overhead Distribution Lines

Number of Cores
xNominal
Cross Section
Phase Conductor Messenger Suspension Unit Continuous
current
rating
at
300C 
ambient
temp
Stranding Nominal
Sectional
Area
Maximum
Conductor
Resistance
Stranding Nominal
Sectional
Area
Breaking
Load
No.×mm² No.×mm mm² Ω/Km No.×mm mm² KN  A
3X50 + 1X25 19/1.78 50 0.641 7/3.0 50 60 116
3X70 + 1X50 19/.14 70 0.443 7/3.15 50 62 210
3X95+ 1X50 19/2.52 95 0.32 7/3.0 50 60 173
3X185+1X120 37/2.52 185 0.164 7/4.67 120 150 259
3X150 +1X50 37/2.25 150 0.206 7/3.15 50 62 365
3X240 +1X50 61/2.25 240 0.125 7/3.15 50 62 500

 Other cross-sections can be offered upon request.
IEC 60502 19/33 kV ABC for Overhead Distribution Lines

Number of Cores
xNominal
Cross Section
Phase Conductor Messenger Suspension Unit Continuous
current
rating
at
300C 
ambient
temp
Stranding Nominal
Sectional
Area
Maximum
Conductor
Resistance
Stranding Nominal
Sectional
Area
Breaking
Load
No.×mm² No.×mm mm² Ω/Km No.×mm mm² KN  A
3X50 + 1X50 19/1.78 50 0.641 7/3.0 50 60 165
3X150+ 1X50 37/2.25 150 0.206 7/3.0 50 60 315
3X185+1X70 37/2.52 185 0.164 7/3.57 70 91 355
3X70 +1X50 19/2.14 7 0.443 7/3.15 50 62 250
3X150 +1X50 37/2.25 150 0.206 7/3.15 50 62 370

 Other cross-sections can be offered upon request.
AS/NZS 3599 Part 1 6.35/11 kV AL/XLPE /HDPE Non-screened Cables

Number of Cores
xNominal
Cross Section
Phase Conductor Messenger
Suspension Unit
Nominal Sectional Area Breaking
Load
Diameter
of
Conductor
Thickness
of
Insulation
Thickness
of
Insulation
Screen
Thickness
of
Sheath
Stranding
No.×mm² mm mm mm mm No.×mm mm² KN
3×35 6.9 3.4 0.8 1.2 7/4.75 52.4 1370
3×50 8.1 3.4 0.8 1.2 7/4.75 54.6 1530
3×70 9.7 3.4 0.8 1.2 7/4.75 57.8 1790
3×95 11.4 3.4 0.8 1.2 7/4.75 61.3 2100
3×120 12.8 3.4 0.8 1.2 19/3.50 67.3 2540
3×150 14.2 3.4 0.8 1.2 19/3.50 70.1 2840
3×185 15.7 3.4 0.8 1.2 19/3.50 73.1 3190

Other cross-sections can be offered upon request.
AS/NZS 3599 Part 1 6.35/11 kV AL/XLPE /CWS/HDPE Screened Cables

Number of Cores
xNominal
Cross Section
Diameter
of
Conductor
Thickness
of
Insulation
Thickness
of
Insulation Screen
Copper Wire Screen
Stranding
Thickness
of
Sheath
Galvanized Steel Wire Stranding Nominal Sectional Area Breaking
Load
No.×mm² mm mm mm No.×mm mm No.×mm mm² KN
Light Duty Screen
3×35 6.9 3.4 0.8 25/0.85 1.8 7/2.00 54.1 1820
3×35 6.9 3.4 0.8 25/0.85 1.8 19/2.00 58.1 2130
3×50 8.1 3.4 0.8 25/0.85 1.8 19/2.00 60.4 2300
3×70 9.7 3.4 0.8 25/0.85 1.8 19/2.00 63.6 2570
3×95 11.4 3.4 0.8 25/0.85 1.8 19/2.00 67.0 2900
3×120 12.8 3.4 0.8 25/0.85 1.8 19/2.00 69.8 3190
3×150 14.2 3.4 0.8 25/0.85 1.9 19/2.00 73.0 3530
3×185 15.7 3.4 0.8 25/0.85 1.9 19/2.00 76.0 3890
Heavy Duty Screen
3×35 6.9 3.4 0.8 40/0.85 1.8 7/2.00 54.1 2050
3×35 6.9 3.4 0.8 40/0.85 1.8 19/2.00 58.1 2360
3×50 8.1 3.4 0.8 23/1.35 1.8 19/2.00 62.4 2820
3×70 9.7 3.4 0.8 32/1.35 1.8 19/2.00 65.6 3440
3×95 11.4 3.4 0.8 39/1.35 1.8 19/2.00 69.0 4030
3×120 12.8 3.4 0.8 39/1.35 1.8 19/2.00 71.8 4320
3×150 14.2 3.4 0.8 39/1.35 1.9 19/2.00 75.0 4670
3×185 15.7 3.4 0.8 39/1.35 1.9 19/2.00 78.0 5020

 Other cross-sections can be offered upon request.
AS/NZS 3599 Part 1 12.7/22 kV AL/XLPE /HDPE Non-screened Cables

Number of Cores
xNominal
Cross Section
Phase Conductor Messenger
Suspension Unit
Nominal Sectional Area Breaking
Load
Diameter
of
Conductor
Thickness
of
Insulation
Thickness
of
Insulation
Screen
Thickness
of
Sheath
Stranding
No.×mm² mm mm mm mm No.×mm mm² KN
3×35 6.9 5.5 0.8 1.2 7/4.75 61.0 1780
3×50 8.1 5.5 0.8 1.2 7/4.75 63.3 1970
3×70 9.7 5.5 0.8 1.2 7/4.75 66.5 2260
3×95 11.4 5.5 0.8 1.2 7/4.75 69.9 2600
3×120 12.8 5.5 0.8 1.2 19/3.50 75.9 3070
3×150 14.2 5.5 0.8 1.2 19/3.50 78.7 3390
3×185 15.7 5.5 0.8 1.2 19/3.50 81.7 3760

 Other cross-sections can be offered upon request.
AS/NZS 3599 Part 1 12.7/22 kV AL/XLPE /CWS/HDPE Screened Cables

Number of Cores
xNominal
Cross Section
Diameter
of
Conductor
Thickness
of
Insulation
Thickness
of
Insulation Screen
Copper Wire
Screen Stranding
Thickness
of
Sheath
Galvanized
Steel Wire Stranding
Nominal Sectional
Area
Breaking
Load
No.×mm² mm mm mm No.×mm mm No.×mm mm² KN
Light Duty Screen
3×35 6.9 5.5 0.8 25/0.85 1.8 7/2.00 62.7 2280
3×35 6.9 5.5 0.8 25/0.85 1.8 19/2.00 66.7 2580
3×50 8.1 5.5 0.8 25/0.85 1.8 19/2.00 69.0 2780
3×70 9.7 5.5 0.8 25/0.85 1.9 19/2.00 72.6 3110
3×95 11.4 5.5 0.8 25/0.85 1.9 19/2.00 76.0 3460
3×120 12.8 5.5 0.8 25/0.85 2.0 19/2.00 79.2 3810
3×150 14.2 5.5 1.0 25/0.85 2.0 19/2.00 82.8 4230
3×185 15.7 5.5 1.0 25/0.85 2.1 19/2.00 86.2 4650
Heavy Duty Screen
3×35 6.9 5.5 0.8 40/0.85 1.8 7/2.00 62.7 2510
3×35 6.9 5.5 0.8 40/0.85 1.8 19/2.00 66.7 2810
3×50 8.1 5.5 0.8 23/1.35 1.8 19/2.00 71.0 3300
3×70 9.7 5.5 0.8 32/1.35 1.9 19/2.00 74.6 3970
3×95 11.4 5.5 0.8 39/1.35 1.9 19/2.00 78.0 4600
3×120 12.8 5.5 0.8 39/1.35 2.0 19/2.00 81.2 4950
3×150 14.2 5.5 1.0 39/1.35 2.0 19/2.00 84.8 5360
3×185 15.7 5.5 1.0 39/1.35 2.1 19/2.00 88.2 5790

Other cross-sections can be offered upon request.
Technical Data

Nominal
Cross Section
Continuous Current Rating
Still air 1m/s wind 2m/s wind
mm² A A A
35 105 145 165
50 125 170 200
70 150 215 250
95 180 260 300
120 205 300 350
150 230 340 395
185 265 390 450

 

Wer wir sind China Einzelner Aluminiumkern 1X16mm2 ABC Kabel PE/PVC-Isolierung Herstellung und Lieferant,Sie können weitere Informationen per E-Mail erhalten, Sie erhalten einen günstigen Preis oder einen Fabrikpreis.

Get Latest Price Request a quote

Popular abc-kabel Produkte

ABC-Kabel, 0,6 kv/1 kv, Aluminium, Service-Drop-Kabel

Overhead XLPE Isolierte Antenne Kabelbündel-ABC

obenliegendes Kabel des Kern 3core 4 ABC-Energien-Kabel-Aluminiumleiter-PVC/PE/XLPE der Isolierungs-2*16mm2 3*35mm2 4*16mm2

Isolierungs-Energien-Kabel des Niederspannung ABC-Kabel-2X10 2X16 obenliegendes XLPE

ABC-Kabel-zusammengerolltes Kabel-Duplex-Triplex/Quadruplex Luftkabel

Aluminiumkern 25mm des leiter-4 XLPE Isolier-ABC-Kabel

Popular Einzelner Aluminiumkern 1X16mm2 ABC Kabel PE/PVC-Isolierung Produkte

  • No related articles
  • Popular Einzelnes Aluminum Core 1X16mm2 Produkte

  • No related articles
  • Popular huatongcable Produkte

    Kupferbeschichteter Stahl/CCS-Leiter 30 % Leitfähigkeit, 40 % Leitfähigkeit 7#7 AWG 7#8 AWG

    1 kv, 11 kv, PVC-XLPE-Kupferkabel

    MV, 20 kv, XLPE, Isoliertes Kupferkabel

    Antennen-Kabelbündel XLPE Isoliert 2 * 120mm2 - AS/NZS 3560.1

    ACSR-Dirigent BS 215 Panther Zebra Wolf Elk

    ACSR-Oberleitung 1/0AWG Raven 2/0AWG Quail

    Tags: , , ,

    SCHNELLER UND ZUVERLÄSSIGER SERVICE FÜR IHR PROJEKT

    Wenden Sie sich noch heute an unsere geschulten Experten, um Ihre perfekte Stromversorgungslösung zu finden.

    STELLE EINE FRAGE